Nondestructive Testing of Harmonic Magnetic Fields in Steel Pipelines Based on Probe Size Adapted Five-Order Response Model

There are difficulties in selecting and designing probe sizes for non-destructive testing of steel pipelines using harmonic magnetic field detection technology under different operating conditions. This study utilized methods such as objective function optimization, the partial derivative of magnetic coupling energy, defect thinning rate, rate of defect extension change in different directions of the pipe, and their integral elements to deeply analyze the influencing factors of the magnetic field excited by the excitation coil vertically placed outside the pipeline. A five-order mathematical response model for pipe diameter, coil diameter, pipe-to-coil distance, defect expansion direction, and its size change was progressively obtained, namely [(d-R-h) - I] to [(d-R-h) - V]. Through these models, the optimal excitation coil size selection scheme for detection probes under different operating conditions was derived. Finally, the effectiveness of the model was verified through experiments with different defect sizes, pipe specifications, and probe lift distances. In addition, a separable pipeline harmonic magnetic field detector was developed, whose coil probe size can be easily replaced to adapt to different detection requirements.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-06-27
DOI
https://doi.org/10.1109/jsen.2025.3577812
Citations
3
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
2.14

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nondestructive Testing of Harmonic Magnetic Fields in Steel Pipelines Based on Probe Size Adapted Five-Order Response Model

Yuchen Shi, Xinbo Yu, Xinhua Wang, Guiming Zhang et al.
3 citations
IEEE Sensors Journal
Non-Destructive Testing Techniques
2.14
article

Nondestructive Testing of Harmonic Magnetic Fields in Steel Pipelines Based on Probe Size Adapted Five-Order Response Model

Yuchen Shi, Xinbo Yu, Xinhua Wang, Guiming Zhang, Zisheng Guo, Zhen Zhang
article en
3 citations

Abstract

There are difficulties in selecting and designing probe sizes for non-destructive testing of steel pipelines using harmonic magnetic field detection technology under different operating conditions. This study utilized methods such as objective function optimization, the partial derivative of magnetic coupling energy, defect thinning rate, rate of defect extension change in different directions of the pipe, and their integral elements to deeply analyze the influencing factors of the magnetic field excited by the excitation coil vertically placed outside the pipeline. A five-order mathematical response model for pipe diameter, coil diameter, pipe-to-coil distance, defect expansion direction, and its size change was progressively obtained, namely [(d-R-h) - I] to [(d-R-h) - V]. Through these models, the optimal excitation coil size selection scheme for detection probes under different operating conditions was derived. Finally, the effectiveness of the model was verified through experiments with different defect sizes, pipe specifications, and probe lift distances. In addition, a separable pipeline harmonic magnetic field detector was developed, whose coil probe size can be easily replaced to adapt to different detection requirements.

IEEE Sensors JournalVol. 25(15)
Beijing Institute of Technology (CN), Beijing University of Technology (CN)
Beijing Municipal Science and Technology Commission
Openalex Percentile: Top 13%
Non-Destructive Testing Techniques
2.14
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nondestructive Testing of Harmonic Magnetic Fields in Steel Pipelines Based on Probe Size Adapted Five-Order Response Model — Yuchen Shi, Xinbo Yu, et al. · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS