An Optimized Controlled Current Source for Cancer Detection using Bioimpedance Spectroscopy

This work presents the design and validation of a Voltage Controlled Current Source (VCCS) aiming the Electrical Bio-Impedance Spectroscopy (EBS) application for Cervical Cancer Detection (CCD). Its topology relies on a modified variety of the classical Howland Current Source, whose schematic and layout were performed in the TSMC 65 nm CMOS process at a standard 1.2 V power supply. In this application, a stable sinusoidal load current must be provided with an amplitude of 10 μA to comply with international electromedical apparatus’ norms (IEC-60601-1) over a wide range of tissue impedance. Therefore, an advanced four-stage Operational Amplifier was customized to fulfill the VCCS’ requirements. The most noteworthy design outcomes were: a robust linearity, compatible with a subsequent 10-bit ADC sampling; a high output impedance, ranging from 1.59 GΩ at 100 Hz up to 159 kΩ at 1 MHz; an AC current amplitude consistently approaching 10 μA with a low DC offset of about ±1 μA for both 10 Ω and 5 kΩ loads at 1 MHz in Monte Carlo simulations; a compact area of 286x82 μm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (without pads); a power dissipation close to 3.7 mW. Consequently, the obtained specifications position the proposed VCCS as an extremely prominent block suitable to be utilized for EBS/CCD.

Authors

Publication Details

Published
2025-05-25
DOI
https://doi.org/10.1109/iscas56072.2025.11043566
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Optimized Controlled Current Source for Cancer Detection using Bioimpedance Spectroscopy

Bruno Sanches, Wilhelmus Adrianus Maria Van Noije, D Castillo
3 links
Electrical and Bioimpedance Tomography
article

An Optimized Controlled Current Source for Cancer Detection using Bioimpedance Spectroscopy

Bruno Sanches, Wilhelmus Adrianus Maria Van Noije, D Castillo
article en

Abstract

This work presents the design and validation of a Voltage Controlled Current Source (VCCS) aiming the Electrical Bio-Impedance Spectroscopy (EBS) application for Cervical Cancer Detection (CCD). Its topology relies on a modified variety of the classical Howland Current Source, whose schematic and layout were performed in the TSMC 65 nm CMOS process at a standard 1.2 V power supply. In this application, a stable sinusoidal load current must be provided with an amplitude of 10 μA to comply with international electromedical apparatus’ norms (IEC-60601-1) over a wide range of tissue impedance. Therefore, an advanced four-stage Operational Amplifier was customized to fulfill the VCCS’ requirements. The most noteworthy design outcomes were: a robust linearity, compatible with a subsequent 10-bit ADC sampling; a high output impedance, ranging from 1.59 GΩ at 100 Hz up to 159 kΩ at 1 MHz; an AC current amplitude consistently approaching 10 μA with a low DC offset of about ±1 μA for both 10 Ω and 5 kΩ loads at 1 MHz in Monte Carlo simulations; a compact area of 286x82 μm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> (without pads); a power dissipation close to 3.7 mW. Consequently, the obtained specifications position the proposed VCCS as an extremely prominent block suitable to be utilized for EBS/CCD.

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Good health and well-being
Openalex Percentile: Top 87%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Optimized Controlled Current Source for Cancer Detection using Bioimpedance Spectroscopy — Bruno Sanches, Wilhelmus Adrianus Maria Van Noije, et al. · (2025) | TGRS Research Map | TGRS