Real-Time Motion Artifact Removal in fNIRS with Denoising Autoencoder at the Edge

Functional near-infrared spectroscopy (fNIRS) can be used to measure cortical hemodynamics, with advantages such as non-invasiveness, high spatial resolution, wearability, ease of use and relatively low cost. These features make it potentially suitable for translational applications such as brain-computer interface (BCI), neurofeedback, and personalized healthcare. However, fNIRS signals are susceptible to motion artifacts (MAs), which can obscure physiological information. Herein, we propose to deploy a denoising autoencoder (DAE) network on an STM32 microcontroller for real-time multichannel MA removal at the edge. The DAE model was trained on fNIRS data augmented with simulated MAs. It was deployed on the edge device without any performance degradation, outperforming the conventional wavelet-based methods. With an inference time of 38 ms, this implementation is well-suited for real-time processing of multi-channel fNIRS data. Additionally, the low memory usage and CPU workload of the model make it ideal for deployment on diverse microcontroller platforms. This work holds the potential to enable the wider applications of wearable fNIRS in practice.

Authors

Institutions

Publication Details

Published
2025-05-25
DOI
https://doi.org/10.1109/iscas56072.2025.11044035
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Motion Artifact Removal in fNIRS with Denoising Autoencoder at the Edge

Hubin Zhao, Robert J. Cooper, Jinchen Li, Yunjia Xia et al.
1 citations
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
article

Real-Time Motion Artifact Removal in fNIRS with Denoising Autoencoder at the Edge

Hubin Zhao, Robert J. Cooper, Jinchen Li, Yunjia Xia, Jingyu Lei
article en
1 citations

Abstract

Functional near-infrared spectroscopy (fNIRS) can be used to measure cortical hemodynamics, with advantages such as non-invasiveness, high spatial resolution, wearability, ease of use and relatively low cost. These features make it potentially suitable for translational applications such as brain-computer interface (BCI), neurofeedback, and personalized healthcare. However, fNIRS signals are susceptible to motion artifacts (MAs), which can obscure physiological information. Herein, we propose to deploy a denoising autoencoder (DAE) network on an STM32 microcontroller for real-time multichannel MA removal at the edge. The DAE model was trained on fNIRS data augmented with simulated MAs. It was deployed on the edge device without any performance degradation, outperforming the conventional wavelet-based methods. With an inference time of 38 ms, this implementation is well-suited for real-time processing of multi-channel fNIRS data. Additionally, the low memory usage and CPU workload of the model make it ideal for deployment on diverse microcontroller platforms. This work holds the potential to enable the wider applications of wearable fNIRS in practice.

University College London (GB)
Openalex Percentile: Top 14%
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.