Revolutionary Unconventional Transmission Line Designs With Higher Line Loadability

Traditionally, overhead AC transmission lines have been used to transfer electrical power from the generation to the distribution sector. The capacitance and inductance of these lines are significantly influenced by the size and arrangement of the subconductors in each phase, which in turn affects the transmission capacity. Conventional transmission lines typically employ a circular symmetry for the arrangement of subconductors in each phase. However, by altering the number and placement of these subconductors, the power transfer capacity of the lines can be significantly increased. Unconventional transmission lines leverage this principle by deviating from the traditional circular symmetry, resulting in a lower characteristic or surge impedance (Zc), which enhances the surge impedance loading (SIL). This paper introduces new designs for unconventional transmission lines, optimized under strict criteria to minimize corona discharge effects while maintaining a narrow corridor width (CW). Compared to a conventional transmission line from the literature—with a SIL of 996 MW and a line width of 24.6 meters (yielding a power density of 40.5 MW/m)—our optimally designed conventional HSIL line achieves a SIL of 1351 MW (a 36% increase) and a line width of only 8.4 meters (a 66% reduction), resulting in a power density of 160.8 MW/m (a 297% increase). Even greater improvements are observed with unconventional HSIL designs, reaching a SIL of 1592 MW—representing a 60% increase over the conventional line and an 18% improvement over the best conventional HSIL design. These findings offer promising prospects for the future of modern transmission networks.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3583915
Citations
1
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Revolutionary Unconventional Transmission Line Designs With Higher Line Loadability

Mona Ghassemi, Mushfiqul Abedin Khan
1 citations
IEEE Access
Thermal Analysis in Power Transmission
1.21
article

Revolutionary Unconventional Transmission Line Designs With Higher Line Loadability

Mona Ghassemi, Mushfiqul Abedin Khan
article en
1 citations

Abstract

Traditionally, overhead AC transmission lines have been used to transfer electrical power from the generation to the distribution sector. The capacitance and inductance of these lines are significantly influenced by the size and arrangement of the subconductors in each phase, which in turn affects the transmission capacity. Conventional transmission lines typically employ a circular symmetry for the arrangement of subconductors in each phase. However, by altering the number and placement of these subconductors, the power transfer capacity of the lines can be significantly increased. Unconventional transmission lines leverage this principle by deviating from the traditional circular symmetry, resulting in a lower characteristic or surge impedance (Zc), which enhances the surge impedance loading (SIL). This paper introduces new designs for unconventional transmission lines, optimized under strict criteria to minimize corona discharge effects while maintaining a narrow corridor width (CW). Compared to a conventional transmission line from the literature—with a SIL of 996 MW and a line width of 24.6 meters (yielding a power density of 40.5 MW/m)—our optimally designed conventional HSIL line achieves a SIL of 1351 MW (a 36% increase) and a line width of only 8.4 meters (a 66% reduction), resulting in a power density of 160.8 MW/m (a 297% increase). Even greater improvements are observed with unconventional HSIL designs, reaching a SIL of 1592 MW—representing a 60% increase over the conventional line and an 18% improvement over the best conventional HSIL design. These findings offer promising prospects for the future of modern transmission networks.

IEEE AccessVol. 13
The University of Texas at Dallas (US)
National Science Foundation
Affordable and clean energy
Openalex Percentile: Top 20%
Thermal Analysis in Power Transmission
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.