Delta-Rule-based Weight Calibration Method for Low-Power SNN System

In this paper, we propose a Spiking Neural Network (SNN) system using a proposed delta rule algorithm-based calibration method to improve accuracy during hardware implementation. The proposed weight calibration cell employs the pulse-driven computation (PDC) method rather than multiply-accumulation (MAC) to perform low-power operations. The PDC organizes the operational part as a counter that performs multiplication operations by counting the number of pulses over a specified time. Compared with existing MAC-based cells, the proposed weight calibration cell enables real-time weight updates without requiring additional memory access, as the counter is capable of performing both computational and memory functions concurrently. This approach results in a significant energy reduction of 95% to 99% and delivers a high energy efficiency of 155 pJ/Train. Additionally, the system achieves stable calibration accuracy, ranging from 94% to 95%, even across diverse accuracy environments.

Authors

Institutions

Publication Details

Published
2025-05-25
DOI
https://doi.org/10.1109/iscas56072.2025.11043655
Primary Topic
Advanced Computing and Algorithms
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Delta-Rule-based Weight Calibration Method for Low-Power SNN System

Minkyu Song, Soo Youn Kim, Seung‐Joon Lee
Advanced Computing and Algorithms
article

Delta-Rule-based Weight Calibration Method for Low-Power SNN System

Minkyu Song, Soo Youn Kim, Seung‐Joon Lee
article en

Abstract

In this paper, we propose a Spiking Neural Network (SNN) system using a proposed delta rule algorithm-based calibration method to improve accuracy during hardware implementation. The proposed weight calibration cell employs the pulse-driven computation (PDC) method rather than multiply-accumulation (MAC) to perform low-power operations. The PDC organizes the operational part as a counter that performs multiplication operations by counting the number of pulses over a specified time. Compared with existing MAC-based cells, the proposed weight calibration cell enables real-time weight updates without requiring additional memory access, as the counter is capable of performing both computational and memory functions concurrently. This approach results in a significant energy reduction of 95% to 99% and delivers a high energy efficiency of 155 pJ/Train. Additionally, the system achieves stable calibration accuracy, ranging from 94% to 95%, even across diverse accuracy environments.

Dongguk University (KR)
Ministry of Education, National Research Foundation of Korea, K2
Affordable and clean energy
Openalex Percentile: Top 80%
Advanced Computing and Algorithms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.