Prospective quality control in chest radiography based on the reconstructed 3D human body

<i>Objective.</i>Chest radiography requires effective quality control (QC) to reduce high retake rates. However, existing QC measures are all retrospective and implemented after exposure, often necessitating retakes when image quality fails to meet standards and thereby increasing radiation exposure to patients. To address this issue, we proposed a 3D human body (3D-HB) reconstruction algorithm to realize prospective QC. Our objective was to investigate the feasibility of using the reconstructed 3D-HB for prospective QC in chest radiography and evaluate its impact on retake rates.<i>Approach.</i>This prospective study included patients indicated for posteroanterior (PA) and lateral (LA) chest radiography in May 2024. A 3D-HB reconstruction algorithm integrating the Skinned Multi-Person Linear eXpressive model and the Hybrid Analytical-Neural Inverse Kinematics eXpressive algorithm was proposed to convert patients' 2D images into 3D-HBs. QC metrics regarding patient positioning and collimation were assessed using chest radiographs (reference standard) and 3D-HBs, with results compared using intraclass correlation coefficients (ICCs), linear regression, and receiver operating characteristic curves. For retake rate evaluation, a real-time 3D-HB visualization interface was developed and chest radiography was conducted in two four-week phases: the first without prospective QC and the second with prospective QC. Retake rates between the two phases were compared using chi-square tests.<i>Main results.</i>324 participants were included (mean age, 42 years ± 19 [SD]; 145 men; 324 PA and 294 LA examinations). The ICCs for the clavicle and midaxillary line angles were 0.80 and 0.78, respectively. Linear regression showed good relation for clavicle angles (<i>R</i><sup>2</sup>: 0.655) and midaxillary line angles (<i>R</i><sup>2</sup>: 0.616). In PA chest radiography, the AUCs of 3D-HBs were 0.89, 0.87, 0.91 and 0.92 for assessing scapula rotation, lateral tilt, centered positioning and central x-ray alignment respectively, with 97% accuracy in collimation assessment. In LA chest radiography, the AUCs of 3D-HBs were 0.87, 0.84, 0.87 and 0.88 for assessing arms raised, chest rotation, centered positioning and central x-ray alignment respectively, with 94% accuracy in collimation assessment. In retake rate evaluation, 3995 PA and 3295 LA chest radiographs were recorded. The implementation of prospective QC based on the 3D-HB reduced retake rates from 8.6% to 3.5% (PA) and 19.6% to 4.9% (LA) (<i>p</i>< .001).<i>Significance.</i>The reconstructed 3D-HB is a feasible tool for prospective QC in chest radiography, providing real-time feedback on patient positioning and collimation before exposure. Prospective QC based on the reconstructed 3D-HB has the potential to reshape the future of radiography QC by significantly reducing retake rates and improving clinical standardization.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-06-27
DOI
https://doi.org/10.1088/1361-6560/ade94c
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective quality control in chest radiography based on the reconstructed 3D human body

Chunchao Xia, Zejun Liang, H. Li, Yuqi Tan et al.
Physics in Medicine and Biology
Radiation Dose and Imaging
article

Prospective quality control in chest radiography based on the reconstructed 3D human body

Chunchao Xia, Zejun Liang, H. Li, Yuqi Tan, Jingyu Ye, Yuzhou Hou, Shaoqing Li, Zheng Ye, Jing Tang, Zhenlin Li
article en

Abstract

<i>Objective.</i>Chest radiography requires effective quality control (QC) to reduce high retake rates. However, existing QC measures are all retrospective and implemented after exposure, often necessitating retakes when image quality fails to meet standards and thereby increasing radiation exposure to patients. To address this issue, we proposed a 3D human body (3D-HB) reconstruction algorithm to realize prospective QC. Our objective was to investigate the feasibility of using the reconstructed 3D-HB for prospective QC in chest radiography and evaluate its impact on retake rates.<i>Approach.</i>This prospective study included patients indicated for posteroanterior (PA) and lateral (LA) chest radiography in May 2024. A 3D-HB reconstruction algorithm integrating the Skinned Multi-Person Linear eXpressive model and the Hybrid Analytical-Neural Inverse Kinematics eXpressive algorithm was proposed to convert patients' 2D images into 3D-HBs. QC metrics regarding patient positioning and collimation were assessed using chest radiographs (reference standard) and 3D-HBs, with results compared using intraclass correlation coefficients (ICCs), linear regression, and receiver operating characteristic curves. For retake rate evaluation, a real-time 3D-HB visualization interface was developed and chest radiography was conducted in two four-week phases: the first without prospective QC and the second with prospective QC. Retake rates between the two phases were compared using chi-square tests.<i>Main results.</i>324 participants were included (mean age, 42 years ± 19 [SD]; 145 men; 324 PA and 294 LA examinations). The ICCs for the clavicle and midaxillary line angles were 0.80 and 0.78, respectively. Linear regression showed good relation for clavicle angles (<i>R</i><sup>2</sup>: 0.655) and midaxillary line angles (<i>R</i><sup>2</sup>: 0.616). In PA chest radiography, the AUCs of 3D-HBs were 0.89, 0.87, 0.91 and 0.92 for assessing scapula rotation, lateral tilt, centered positioning and central x-ray alignment respectively, with 97% accuracy in collimation assessment. In LA chest radiography, the AUCs of 3D-HBs were 0.87, 0.84, 0.87 and 0.88 for assessing arms raised, chest rotation, centered positioning and central x-ray alignment respectively, with 94% accuracy in collimation assessment. In retake rate evaluation, 3995 PA and 3295 LA chest radiographs were recorded. The implementation of prospective QC based on the 3D-HB reduced retake rates from 8.6% to 3.5% (PA) and 19.6% to 4.9% (LA) (<i>p</i>< .001).<i>Significance.</i>The reconstructed 3D-HB is a feasible tool for prospective QC in chest radiography, providing real-time feedback on patient positioning and collimation before exposure. Prospective QC based on the reconstructed 3D-HB has the potential to reshape the future of radiography QC by significantly reducing retake rates and improving clinical standardization.

Physics in Medicine and BiologyVol. 70(14)
Sichuan University (CN), West China Hospital of Sichuan University (CN), Hongzhiwei Technology (China) (CN)
West China Hospital, Sichuan University
Openalex Percentile: Top 77%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.