Photoacoustic and Fiber-Optic Interferometer Spectroscopic Method for Simultaneous Detection of Multiple Trace Gases

Dissolved gases in transformer oil are reliable indicators of operating conditions and fault types. Additionally, ambient water vapor can seriously affect the accuracy of photoacoustic dissolved gas analysis systems. Therefore, there is an urgent need for the development of the simultaneous detection of dissolved gases and water. A high-sensitivity, multiple-gas sensing system was developed by combining a differential photoacoustic cell and a water vapor fiber-optic sensor. The acoustic properties of the designed differential photoacoustic cell were analyzed through simulation and experimental validation for the differential and longitudinal modes, and the frequency difference between excitation and nonexcitation optical paths in the longitudinal mode was leveraged, achieving an amplitude response comparable to that of the differential mode. C<sub>2</sub>H<sub>2</sub>, CH<sub>4</sub>, and CO measurements were performed at three resonance frequencies using two DFB and a QCL source. To monitor H<sub>2</sub>O concentration and evaluate its effect on photoacoustic detection, a fiber-optic Fabry-Perot interferometer was developed using self-assembled microspheres with high specific surface area, single-mode optical fibers, and concentric tapered capillary tubes. Water vapor adsorption on the microspheres altered the refractive index, and cavity-length demodulation was employed to analyze the interference spectra to obtain the water vapor concentration. The water optical sensor showed high sensitivity of ∼112 pm/% for H<sub>2</sub>O detection. Experimental results demonstrated that the dual-mode multicomponent gas sensor can achieve detection limits of 1.15, 241.07, and 367.32 ppb for CO, C<sub>2</sub>H<sub>2</sub>, and CH<sub>4</sub>, respectively, with corresponding normalized equivalent noise absorption coefficients of 1.53 × 10<sup>-8</sup> cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>, 4.56 × 10<sup>-9</sup> cm<sup>-1</sup>·W· Hz<sup>-1/2</sup>, and 3.75 × 10<sup>-9</sup> cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-06-27
DOI
https://doi.org/10.1021/acs.analchem.5c02177
Citations
4
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
3.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photoacoustic and Fiber-Optic Interferometer Spectroscopic Method for Simultaneous Detection of Multiple Trace Gases

Huiting Huan, Xuesen Xu, Lixian Liu, Huailiang Xu et al.
4 citations
Analytical Chemistry
Spectroscopy and Laser Applications
3.03
article

Photoacoustic and Fiber-Optic Interferometer Spectroscopic Method for Simultaneous Detection of Multiple Trace Gases

Huiting Huan, Xuesen Xu, Lixian Liu, Huailiang Xu, Xueshi Zhang, Ying Yue, Yifan Li, Yimeng Zhang, Lingmin Zhang, Le Zhang, Jialiang Sun, Andreas Mandelis
article en
4 citations

Abstract

Dissolved gases in transformer oil are reliable indicators of operating conditions and fault types. Additionally, ambient water vapor can seriously affect the accuracy of photoacoustic dissolved gas analysis systems. Therefore, there is an urgent need for the development of the simultaneous detection of dissolved gases and water. A high-sensitivity, multiple-gas sensing system was developed by combining a differential photoacoustic cell and a water vapor fiber-optic sensor. The acoustic properties of the designed differential photoacoustic cell were analyzed through simulation and experimental validation for the differential and longitudinal modes, and the frequency difference between excitation and nonexcitation optical paths in the longitudinal mode was leveraged, achieving an amplitude response comparable to that of the differential mode. C<sub>2</sub>H<sub>2</sub>, CH<sub>4</sub>, and CO measurements were performed at three resonance frequencies using two DFB and a QCL source. To monitor H<sub>2</sub>O concentration and evaluate its effect on photoacoustic detection, a fiber-optic Fabry-Perot interferometer was developed using self-assembled microspheres with high specific surface area, single-mode optical fibers, and concentric tapered capillary tubes. Water vapor adsorption on the microspheres altered the refractive index, and cavity-length demodulation was employed to analyze the interference spectra to obtain the water vapor concentration. The water optical sensor showed high sensitivity of ∼112 pm/% for H<sub>2</sub>O detection. Experimental results demonstrated that the dual-mode multicomponent gas sensor can achieve detection limits of 1.15, 241.07, and 367.32 ppb for CO, C<sub>2</sub>H<sub>2</sub>, and CH<sub>4</sub>, respectively, with corresponding normalized equivalent noise absorption coefficients of 1.53 × 10<sup>-8</sup> cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>, 4.56 × 10<sup>-9</sup> cm<sup>-1</sup>·W· Hz<sup>-1/2</sup>, and 3.75 × 10<sup>-9</sup> cm<sup>-1</sup>·W·Hz<sup>-1/2</sup>.

Analytical ChemistryVol. 97(27)
Xidian University (CN), Xi'an Shiyou University (CN), University of Toronto (CA), Institute for Advanced Study (DE), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Natural Sciences and Engineering Research Council of Canada, Fundamental Research Funds for the Central Universities, Natural Science Foundation of Zhejiang Province
Openalex Percentile: Top 9%
Spectroscopy and Laser Applications
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.