Illegal drugs sensor: Performance evaluation and identification based on terahertz photonic crystal fiber

Excessive hormone release, the possibility of sleep disturbances, and a brief and quick improvement in the functioning of many organs, the physiological system, the nerves, etc. are all consequences of the abuse of incentive medications. Illegal narcotics have terrible long-term impacts on human health, including the possibility of death, in addition to their immediate effects. These consequences highlight the need for more obviousness and accuracy in the detection of illicit drugs, as well as for their detection to be done gently, effectively, and consistently. This work introduces an illicit drug sensor based on PCF, with an eye toward these as the primary targets. Three illegal drugs - ketamine, amphetamine, and cocaine - have been simulated for the sensor. Two types of circular air holes in cladding of varying sizes have been developed for a single core PCF. The cladding has three-layer chain and wind turbine-shaped air holes, and a circular air hole in the core region that will be used to field test drug samples, all included to achieve low confinement losses and high sensitivity. A maximum Relative Sensitivity (RS) of 99.92%, 99.12% and 98.83% at ketamine, amphetamine, and cocaine respectively is revealed by the recently established PCF analysis, which was presented out right away. Furthermore, we looked at the Confinement Loss (CL) associated with these illicit drugs, which was around 1.275 × 10-7 dB/m, 2.653 × 10-9 dB/m, and 4.106 × 10-10 dB/m, besides Effective Material Loss (EML) of 0.0042 cm-1, 0.0044 cm-1 and 0.0045 cm-1. Refractive index changes in PCF are usually the cause of action for PCF-based biosensors. These modifications have an impact on how light travels within the fiber. Drug molecules interact with light as a result of changes in the optical properties of the core that occur during light propagation through it.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-06-27
DOI
https://doi.org/10.1371/journal.pone.0327013
Citations
2
Primary Topic
Photonic Crystal and Fiber Optics
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Illegal drugs sensor: Performance evaluation and identification based on terahertz photonic crystal fiber

A. H. M. Iftekharul Ferdous, Mohammad Omar Faruk, Md. Feroz Ali, Taheri Hasan et al.
2 citations
PLoS ONE
Photonic Crystal and Fiber Optics
1.46
article

Illegal drugs sensor: Performance evaluation and identification based on terahertz photonic crystal fiber

A. H. M. Iftekharul Ferdous, Mohammad Omar Faruk, Md. Feroz Ali, Taheri Hasan, Diponkar Kundu, Kayab Khandakar, Jabin Tasnin Upoma, Md. Shahorin Islam Shaun
article en
2 citations

Abstract

Excessive hormone release, the possibility of sleep disturbances, and a brief and quick improvement in the functioning of many organs, the physiological system, the nerves, etc. are all consequences of the abuse of incentive medications. Illegal narcotics have terrible long-term impacts on human health, including the possibility of death, in addition to their immediate effects. These consequences highlight the need for more obviousness and accuracy in the detection of illicit drugs, as well as for their detection to be done gently, effectively, and consistently. This work introduces an illicit drug sensor based on PCF, with an eye toward these as the primary targets. Three illegal drugs - ketamine, amphetamine, and cocaine - have been simulated for the sensor. Two types of circular air holes in cladding of varying sizes have been developed for a single core PCF. The cladding has three-layer chain and wind turbine-shaped air holes, and a circular air hole in the core region that will be used to field test drug samples, all included to achieve low confinement losses and high sensitivity. A maximum Relative Sensitivity (RS) of 99.92%, 99.12% and 98.83% at ketamine, amphetamine, and cocaine respectively is revealed by the recently established PCF analysis, which was presented out right away. Furthermore, we looked at the Confinement Loss (CL) associated with these illicit drugs, which was around 1.275 × 10-7 dB/m, 2.653 × 10-9 dB/m, and 4.106 × 10-10 dB/m, besides Effective Material Loss (EML) of 0.0042 cm-1, 0.0044 cm-1 and 0.0045 cm-1. Refractive index changes in PCF are usually the cause of action for PCF-based biosensors. These modifications have an impact on how light travels within the fiber. Drug molecules interact with light as a result of changes in the optical properties of the core that occur during light propagation through it.

PLoS ONEVol. 20(6)
Pabna University of Science and Technology (BD)
Good health and well-being
Openalex Percentile: Top 17%
Photonic Crystal and Fiber Optics
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.