T2 contrast variation in human brain at 7 T and its potential contributors

Magnetic susceptibility-weighted MRI (or T<sub>2</sub> <sup>*</sup>-weighted MRI) at 7 T and higher field strengths has shown superb sensitivity to study normal and pathological levels of non-heme (tissue) iron and myelin in the brain. However, macroscopic field perturbations originating from venous vasculature and tissue-air interfaces lead to image artifacts, posing strong confounds to the interpretation of T<sub>2</sub> <sup>*</sup> contrast. Use of T<sub>2</sub>-based rather than the more common T<sub>2</sub> <sup>*</sup>-based contrast to study susceptibility perturbations may alleviate these adverse effects, but it is technically challenging at high fields. The latter relates to the difficulty in performing accurate RF refocusing in the presence of increased B<sub>0</sub>- and B<sub>1</sub>-non-uniformity, and limits on RF power deposition. To overcome this, we employed the Gradient Echo Sampling of Spin Echo (GESSE) method to study R<sub>2</sub> (=1/T<sub>2</sub>) variations at 7 T in healthy human brain. Our results indicate that sensitivity of R<sub>2</sub> to tissue iron, and associated tissue contrast, is largely preserved across subcortical structures, cortical functional areas, and between the cortex and superficial white matter, with substantially reduced sensitivity to macroscopic susceptibility effects. Therefore, R<sub>2</sub> as measured by GESSE may complement current R<sub>2</sub> <sup>*</sup>- and χ-based approaches for quantification of brain tissue iron and myelin. In deep white matter, R<sub>2</sub> was found to exhibit fiber bundle specificity, and showed significant correlations with documented fiber diameter and inferred orientation dependence with respect to the B<sub>0</sub>. These results comprehensively chart multiple main contributors to R<sub>2</sub> contrast at 7 T across the whole brain, extending previous studies that have done so in specific brain areas or at lower field. Quantitative interpretation of R<sub>2</sub> contrast in terms of tissue iron and myelin content needs to take all these contributors into account.

Authors

Institutions

Publication Details

Journal
Imaging Neuroscience
Published
2025-01-01
DOI
https://doi.org/10.1162/imag.a.67
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

T2 contrast variation in human brain at 7 T and its potential contributors

Maxime Donadieu, Daniel S. Reich, Jacco A. de Zwart, Jiazheng Zhou et al.
Imaging Neuroscience
Advanced MRI Techniques and Applications
article

T2 contrast variation in human brain at 7 T and its potential contributors

Maxime Donadieu, Daniel S. Reich, Jacco A. de Zwart, Jiazheng Zhou, Yicun Wang, Govind Nair, Jiaen Liu, Peter van Gelderen, Jeff H. Duyn
article en

Abstract

Magnetic susceptibility-weighted MRI (or T<sub>2</sub> <sup>*</sup>-weighted MRI) at 7 T and higher field strengths has shown superb sensitivity to study normal and pathological levels of non-heme (tissue) iron and myelin in the brain. However, macroscopic field perturbations originating from venous vasculature and tissue-air interfaces lead to image artifacts, posing strong confounds to the interpretation of T<sub>2</sub> <sup>*</sup> contrast. Use of T<sub>2</sub>-based rather than the more common T<sub>2</sub> <sup>*</sup>-based contrast to study susceptibility perturbations may alleviate these adverse effects, but it is technically challenging at high fields. The latter relates to the difficulty in performing accurate RF refocusing in the presence of increased B<sub>0</sub>- and B<sub>1</sub>-non-uniformity, and limits on RF power deposition. To overcome this, we employed the Gradient Echo Sampling of Spin Echo (GESSE) method to study R<sub>2</sub> (=1/T<sub>2</sub>) variations at 7 T in healthy human brain. Our results indicate that sensitivity of R<sub>2</sub> to tissue iron, and associated tissue contrast, is largely preserved across subcortical structures, cortical functional areas, and between the cortex and superficial white matter, with substantially reduced sensitivity to macroscopic susceptibility effects. Therefore, R<sub>2</sub> as measured by GESSE may complement current R<sub>2</sub> <sup>*</sup>- and χ-based approaches for quantification of brain tissue iron and myelin. In deep white matter, R<sub>2</sub> was found to exhibit fiber bundle specificity, and showed significant correlations with documented fiber diameter and inferred orientation dependence with respect to the B<sub>0</sub>. These results comprehensively chart multiple main contributors to R<sub>2</sub> contrast at 7 T across the whole brain, extending previous studies that have done so in specific brain areas or at lower field. Quantitative interpretation of R<sub>2</sub> contrast in terms of tissue iron and myelin content needs to take all these contributors into account.

Imaging NeuroscienceVol. 3
National Institutes of Health (US), Stony Brook School (US), National Institute of Neurological Disorders and Stroke (US), Advanced Imaging Research (United States) (US), Southwestern Medical Center (US), Stony Brook University (US), The University of Texas Southwestern Medical Center (US)
Johns Hopkins University, National Institutes of Health, National Institute of Neurological Disorders and Stroke
Openalex Percentile: Top 77%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.