Direct Cardiac Compression Device for Short-Term Mechanical Circulatory Support

Patients requiring short-term ventricular assistance have limited options. While not all interventions necessarily require blood-contacting support, all current devices are invasive and interact with the bloodstream. Direct cardiac compression (DCC) devices offer a potential solution by providing mechanical circulatory support (MCS) without contact with the bloodstream. This proof-of-concept study compares a novel DCC patch device for short-term MCS to open-chest cardiac compression (OCCC) using an ex vivo ovine cardiac arrest (CA) heart model. Performance is evaluated by assessing pressure, flow rate, and valve functionality, as well as any damage to the tissue. In the CA model, the device achieves 1.5 L/min cardiac output and a mean aortic pressure of 55 mm Hg. Despite direct epicardial contact, the DCC patch device maintains effective valve function. This study demonstrates that the DCC patch device achieves comparable performance to OCCC, supporting previous in vitro findings. Our results suggest the potential for this novel DCC patch device to be applied across a range of short-term MCS scenarios.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2025-06-27
DOI
https://doi.org/10.1097/mat.0000000000002493
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Cardiac Compression Device for Short-Term Mechanical Circulatory Support

Thomas Kummer, Patrick Jenny, Stefanos Demertzis, Stijn Vandenberghe et al.
ASAIO Journal
Cardiac Arrest and Resuscitation
article

Direct Cardiac Compression Device for Short-Term Mechanical Circulatory Support

Thomas Kummer, Patrick Jenny, Stefanos Demertzis, Stijn Vandenberghe, Kristof Sarosi
article en

Abstract

Patients requiring short-term ventricular assistance have limited options. While not all interventions necessarily require blood-contacting support, all current devices are invasive and interact with the bloodstream. Direct cardiac compression (DCC) devices offer a potential solution by providing mechanical circulatory support (MCS) without contact with the bloodstream. This proof-of-concept study compares a novel DCC patch device for short-term MCS to open-chest cardiac compression (OCCC) using an ex vivo ovine cardiac arrest (CA) heart model. Performance is evaluated by assessing pressure, flow rate, and valve functionality, as well as any damage to the tissue. In the CA model, the device achieves 1.5 L/min cardiac output and a mean aortic pressure of 55 mm Hg. Despite direct epicardial contact, the DCC patch device maintains effective valve function. This study demonstrates that the DCC patch device achieves comparable performance to OCCC, supporting previous in vitro findings. Our results suggest the potential for this novel DCC patch device to be applied across a range of short-term MCS scenarios.

ASAIO Journal
ETH Zurich (CH), Ente Ospedaliero Cantonale (CH), Università della Svizzera italiana (CH)
Good health and well-being
Openalex Percentile: Top 76%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Direct Cardiac Compression Device for Short-Term Mechanical Circulatory Support — Thomas Kummer, Patrick Jenny, et al. · ASAIO Journal (2025) | TGRS Research Map | TGRS