Smartphone‐Assisted Thin‐Layer Chromatography for Rapid Quality Screening of Metformin

Type II diabetes remains a significant global public health issue, affecting both individual well-being and healthcare systems worldwide. Metformin hydrochloride is widely prescribed as the first-line treatment for managing diabetes. However, the increasing reports of substandard and falsified medicines, including metformin, circulating in the markets in recent years, highlights the urgent need for reliable and portable quality assurance tools. Thin-layer chromatography (TLC) has long been extensively used as a screening method to verify the identity and quality of various medicines. In this work, we present a smartphone-assisted TLC method for quantitative analysis of metformin hydrochloride. The TLC was performed using silica gel 60 F<sub>254</sub> plates as the stationary phase and acetic acid-methanol-water 0.25:7:4 (v/v) as a mobile phase. We used a custom-made UV-illuminated TLC imaging box to capture images via smartphone and images were analyzed using a custom written smartphone application to calculate the <i>R</i> <sub><i>f</i></sub> and the concentration of metformin in the principal TLC spots. The smartphone application, <i>TLC Analyzer</i>, accurately calculated the <i>R</i> <sub><i>f</i></sub> values (0.604) consistent with those obtained using ImageJ software. The linearity of the method was 0.5-4 mg/mL. After optimization, the <i>TLC Analyzer</i> method was used to analyze metformin samples (<i>n</i> = 16) collected from local pharmacies. The results were compared with those from ImageJ analysis, UV-Vis spectrophotometry, and HPLC. The smartphone-based <i>TLC Analyzer</i> method identified 15 of the 16 samples as containing acceptable levels of metformin in accordance with pharmacopeial standards, consistent with ImageJ and spectrophotometric results. In contrast, the HPLC method indicated that all 16 samples met the pharmacopeial criteria.

Authors

Institutions

Publication Details

Journal
Advances in Pharmacological and Pharmaceutical Sciences
Published
2025-01-01
DOI
https://doi.org/10.1155/adpp/3306550
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartphone‐Assisted Thin‐Layer Chromatography for Rapid Quality Screening of Metformin

Toni Barstis, Ram Kumar Bhattarai, Sanam Pudasaini, Basant Giri
Advances in Pharmacological and Pharmaceutical Sciences
Analytical Chemistry and Chromatography
article

Smartphone‐Assisted Thin‐Layer Chromatography for Rapid Quality Screening of Metformin

Toni Barstis, Ram Kumar Bhattarai, Sanam Pudasaini, Basant Giri
article en

Abstract

Type II diabetes remains a significant global public health issue, affecting both individual well-being and healthcare systems worldwide. Metformin hydrochloride is widely prescribed as the first-line treatment for managing diabetes. However, the increasing reports of substandard and falsified medicines, including metformin, circulating in the markets in recent years, highlights the urgent need for reliable and portable quality assurance tools. Thin-layer chromatography (TLC) has long been extensively used as a screening method to verify the identity and quality of various medicines. In this work, we present a smartphone-assisted TLC method for quantitative analysis of metformin hydrochloride. The TLC was performed using silica gel 60 F<sub>254</sub> plates as the stationary phase and acetic acid-methanol-water 0.25:7:4 (v/v) as a mobile phase. We used a custom-made UV-illuminated TLC imaging box to capture images via smartphone and images were analyzed using a custom written smartphone application to calculate the <i>R</i> <sub><i>f</i></sub> and the concentration of metformin in the principal TLC spots. The smartphone application, <i>TLC Analyzer</i>, accurately calculated the <i>R</i> <sub><i>f</i></sub> values (0.604) consistent with those obtained using ImageJ software. The linearity of the method was 0.5-4 mg/mL. After optimization, the <i>TLC Analyzer</i> method was used to analyze metformin samples (<i>n</i> = 16) collected from local pharmacies. The results were compared with those from ImageJ analysis, UV-Vis spectrophotometry, and HPLC. The smartphone-based <i>TLC Analyzer</i> method identified 15 of the 16 samples as containing acceptable levels of metformin in accordance with pharmacopeial standards, consistent with ImageJ and spectrophotometric results. In contrast, the HPLC method indicated that all 16 samples met the pharmacopeial criteria.

Advances in Pharmacological and Pharmaceutical SciencesVol. 2025(1)
Kathmandu University (NP), Saint Mary's College (US)
Division of Chemistry
Openalex Percentile: Top 86%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.