INCREASED CONTACT RESISTANCE IN ELECTRICAL NETWORKS AS A CAUSE OF FIRES

Problem statement. The article focuses on the actual problem of increased fire hazard of power grids of old buildings in Odesa and Lviv, which is associated with an increase in electrical load and the presence of areas with high transient resistance (TR). Based on the analysis of electrophysical parameters, a method for assessing the state of power grids is proposed, which allows timely detection of emergency areas with HTR.Research methods. To detect areas with increased transient resistance (TR) in hidden low-voltage power grids (up to 1000 V inclusive), we propose to use a diagnostic approach based on the analysis of the ratio between the input electrical power supplied to the consumer load and the power directly consumed by this load. The methodology involves comparing the input and output voltages with the calculation of the fire hazard factor, which determines the input power to output power ratio, i.e. the proportion of energy that does not reach the load and is lost to heating.Results. An increase in the fire hazard factor indicates an increase in losses in the network, which, in turn, may indicate a decrease in the cross-section of conductors, oxidation of contacts, or areas with critical transient resistance. Experimental studies of the power distribution network with areas of high transient resistance confirm the effectiveness of this approach for diagnosing hidden networks with voltages up to 1000 V. A photo of the experimental setup for determining the emergency state of a hidden electrical network is shown. Scientific significance. The proposed approach makes it possible to prevent the emergence of fires in intra-building electrical networks and reduce the risk of fires caused by the thermal effect of electrical energy, that is, to minimize the possibility of fires in buildings, in particular in historical heritage sites.

Authors

Publication Details

Journal
Bulletin of Lviv State University of Life Safety
Published
2025-01-01
DOI
https://doi.org/10.32447/20784643.31.2025.16
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INCREASED CONTACT RESISTANCE IN ELECTRICAL NETWORKS AS A CAUSE OF FIRES

A. V. Bespalova, Olha Dashkovska, O. I. Knysh, I.O. Myliutchenko et al.
4 links
Bulletin of Lviv State University of Life Safety
Electrical Fault Detection and Protection
article

INCREASED CONTACT RESISTANCE IN ELECTRICAL NETWORKS AS A CAUSE OF FIRES

A. V. Bespalova, Olha Dashkovska, O. I. Knysh, I.O. Myliutchenko, O. B. Нornostaі
article en

Abstract

Problem statement. The article focuses on the actual problem of increased fire hazard of power grids of old buildings in Odesa and Lviv, which is associated with an increase in electrical load and the presence of areas with high transient resistance (TR). Based on the analysis of electrophysical parameters, a method for assessing the state of power grids is proposed, which allows timely detection of emergency areas with HTR.Research methods. To detect areas with increased transient resistance (TR) in hidden low-voltage power grids (up to 1000 V inclusive), we propose to use a diagnostic approach based on the analysis of the ratio between the input electrical power supplied to the consumer load and the power directly consumed by this load. The methodology involves comparing the input and output voltages with the calculation of the fire hazard factor, which determines the input power to output power ratio, i.e. the proportion of energy that does not reach the load and is lost to heating.Results. An increase in the fire hazard factor indicates an increase in losses in the network, which, in turn, may indicate a decrease in the cross-section of conductors, oxidation of contacts, or areas with critical transient resistance. Experimental studies of the power distribution network with areas of high transient resistance confirm the effectiveness of this approach for diagnosing hidden networks with voltages up to 1000 V. A photo of the experimental setup for determining the emergency state of a hidden electrical network is shown. Scientific significance. The proposed approach makes it possible to prevent the emergence of fires in intra-building electrical networks and reduce the risk of fires caused by the thermal effect of electrical energy, that is, to minimize the possibility of fires in buildings, in particular in historical heritage sites.

Bulletin of Lviv State University of Life SafetyVol. 31
Affordable and clean energy
Openalex Percentile: Top 87%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

INCREASED CONTACT RESISTANCE IN ELECTRICAL NETWORKS AS A CAUSE OF FIRES — A. V. Bespalova, Olha Dashkovska, et al. · Bulletin of Lviv State University of Life Safety (2025) | TGRS Research Map | TGRS