Fabrication and Testing of a 64-Element CMUT Ring Array for Underwater Ultrasound Imaging

Capacitive Micromachined Ultrasonic Transducers (CMUTs) have demonstrated great potential in ultrasonic imaging due to their wide bandwidth, high electromechanical coupling coefficient, flexible design, and ease of integration. However, traditional CMUT devices require high drive voltages, which may pose potential safety risks to humans and limit their widespread application in imaging fields. To address this issue, this study innovatively designs and fabricates a large-diameter (20 cm) CMUT annular array with low drive voltage (25 V DC and 15 V AC). Finite element simulation results show that the collapse voltage of the CMUT is 52 V. Devices fabricated using wafer bonding technology exhibit excellent linear I-V characteristics and a "U" shaped C-V curve. In air, the resonant frequency is 4.71 MHz; after PDMS electrical insulation encapsulation, the resonant frequency drops to 2.74 MHz when submerged in water. The fabricated CMUT elements exhibit a −6 dB bandwidth of 118%, a −6 dB beamwidth of 13°, and a receive sensitivity of −205 dB @2.5 MHz. The maximum normalized consistency error among the 64 array elements is 0.3. In the underwater imaging experiment, five targets with varying sizes, positions, and sound speeds embedded in a tissue-mimicking phantom were successfully reconstructed. The maximum radial error in the reconstructed target center positions was 5%. These results demonstrate that the designed low-voltage CMUT ring array possesses excellent imaging performance and significant potential for underwater ultrasound imaging applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3583366
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication and Testing of a 64-Element CMUT Ring Array for Underwater Ultrasound Imaging

Changde He, Renxin Wang, Licheng Jia, Mehmet Yılmaz et al.
2 links
IEEE Transactions on Instrumentation and Measurement
Ultrasonics and Acoustic Wave Propagation
article

Fabrication and Testing of a 64-Element CMUT Ring Array for Underwater Ultrasound Imaging

Changde He, Renxin Wang, Licheng Jia, Mehmet Yılmaz, Guojun Zhang, Zhaodong Li, Zhihao Wang, Shurui Liu, Jingwen Wang, Wendong Zhang, Chenya Zhao, Li Qin, Xiangbin Zeng
article en

Abstract

Capacitive Micromachined Ultrasonic Transducers (CMUTs) have demonstrated great potential in ultrasonic imaging due to their wide bandwidth, high electromechanical coupling coefficient, flexible design, and ease of integration. However, traditional CMUT devices require high drive voltages, which may pose potential safety risks to humans and limit their widespread application in imaging fields. To address this issue, this study innovatively designs and fabricates a large-diameter (20 cm) CMUT annular array with low drive voltage (25 V DC and 15 V AC). Finite element simulation results show that the collapse voltage of the CMUT is 52 V. Devices fabricated using wafer bonding technology exhibit excellent linear I-V characteristics and a "U" shaped C-V curve. In air, the resonant frequency is 4.71 MHz; after PDMS electrical insulation encapsulation, the resonant frequency drops to 2.74 MHz when submerged in water. The fabricated CMUT elements exhibit a −6 dB bandwidth of 118%, a −6 dB beamwidth of 13°, and a receive sensitivity of −205 dB @2.5 MHz. The maximum normalized consistency error among the 64 array elements is 0.3. In the underwater imaging experiment, five targets with varying sizes, positions, and sound speeds embedded in a tissue-mimicking phantom were successfully reconstructed. The maximum radial error in the reconstructed target center positions was 5%. These results demonstrate that the designed low-voltage CMUT ring array possesses excellent imaging performance and significant potential for underwater ultrasound imaging applications.

IEEE Transactions on Instrumentation and MeasurementVol. 74
North University of China (CN), Bilkent University (TR)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 83%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.