Virtual Radar Model and Processing for All-Directional Measurements of Vital Signs

To address the limitations of the radar horizontal field of view (HFOV), this article proposes a novel virtual frequency-modulated continuous-wave (FMCW) radar model to achieve simultaneous all-directional measurements through the integration of rotation motor and radar. However, weak vital signs are susceptible to interference from vibrations caused by the torque ripple of motor, which leads to the generation of ghost objects and phase noise interference. First, a Doppler combination filtering (DCF) method is proposed to localize the subjects and suppress interference from torque ripple vibrations, utilizing multiple Doppler frequencies associated with breathing for improved precision. Second, an adaptive convergence variational mode extraction-weight pair accumulation (ACVME-WPA) method is proposed to separate breathing and heartbeat signals from the phase signal affected by motor vibration. This method incorporates two key ideas: one involves determining the adjustment rate of the penalty value based on the iterative differences between center frequencies, the other focuses on aggregating multiple phase signals using weighted pairs to enhance performance by considering the HFOV overlap of adjacent virtual radars. Experimental results show that the proposed methods can achieve all-directional measurements of localization,respiration rate (RR), and heartbeat rate (HR) for single subjects with varied breathing patterns, with HR mean absolute error (MAE) of 0.026 Hz in the breath-holding experiment, and also work well for multi-person scenarios with different angles and window lengths. In the four subjects experiment, the proposed method still works even when subjects aren’t facing the radar. For rightside orientation, the RR and HR MAEs were 0.007 Hz and 0.025 Hz respectively.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3583384
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Virtual Radar Model and Processing for All-Directional Measurements of Vital Signs

Yingjie Ye, Danke Jiang, S. L. Tu, Zhenyu Liu
IEEE Transactions on Instrumentation and Measurement
Non-Invasive Vital Sign Monitoring
article

Virtual Radar Model and Processing for All-Directional Measurements of Vital Signs

Yingjie Ye, Danke Jiang, S. L. Tu, Zhenyu Liu
article en

Abstract

To address the limitations of the radar horizontal field of view (HFOV), this article proposes a novel virtual frequency-modulated continuous-wave (FMCW) radar model to achieve simultaneous all-directional measurements through the integration of rotation motor and radar. However, weak vital signs are susceptible to interference from vibrations caused by the torque ripple of motor, which leads to the generation of ghost objects and phase noise interference. First, a Doppler combination filtering (DCF) method is proposed to localize the subjects and suppress interference from torque ripple vibrations, utilizing multiple Doppler frequencies associated with breathing for improved precision. Second, an adaptive convergence variational mode extraction-weight pair accumulation (ACVME-WPA) method is proposed to separate breathing and heartbeat signals from the phase signal affected by motor vibration. This method incorporates two key ideas: one involves determining the adjustment rate of the penalty value based on the iterative differences between center frequencies, the other focuses on aggregating multiple phase signals using weighted pairs to enhance performance by considering the HFOV overlap of adjacent virtual radars. Experimental results show that the proposed methods can achieve all-directional measurements of localization,respiration rate (RR), and heartbeat rate (HR) for single subjects with varied breathing patterns, with HR mean absolute error (MAE) of 0.026 Hz in the breath-holding experiment, and also work well for multi-person scenarios with different angles and window lengths. In the four subjects experiment, the proposed method still works even when subjects aren’t facing the radar. For rightside orientation, the RR and HR MAEs were 0.007 Hz and 0.025 Hz respectively.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Guangdong University of Technology (CN)
Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 86%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.