Influences of Human Presence on the Indoor Air Quality of Educational Institutions: Concurrent Multipollutant Sensing Approach
This study evaluates how human presence influences classroom air quality using an edge-intelligent, low-cost monitoring system (AQMS) that senses multiple pollutants and quantifies occupancy with an on-board camera and custom object-detection model. Over seven days in a laboratory, we varied air-conditioning and ventilation settings while the AQMS logged pollutant levels every minute. Spearman rank-order analysis showed strong positive correlations between occupancy and CO2, total VOCs, and gas-sensor resistance, but no significant link with CO, NH3, or NO2. Particulate matter (PM2.5, PM10) briefly fell as occupancy rose, yet this trend vanished when air-conditioning was active, indicating its filtration effect. Rooms without air-conditioning but with adequate ventilation maintained lower CO2 and VOC levels. PM findings were inconclusive because of concurrent inhalation effects. All occupancy data were privacy-preserving—images were processed on device and never stored. Although demonstrated in a single room, the architecture is inherently scalable, and a multi-room urban–rural deployment is underway.
Authors
- Shubhankar Majumdar (ORCID: https://orcid.org/0000-0002-3703-4904)
- Aritra Acharyya (ORCID: https://orcid.org/0000-0003-0231-4145)
- Rajib Das (ORCID: https://orcid.org/0009-0002-8315-5165)
Institutions
- Cooch Behar Panchanan Barma University (IN)
- University of Kalyani (IN)
- National Institute of Technology Meghalaya (IN)
Publication Details
- Journal
- IEEE Open Journal of Instrumentation and Measurement
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/ojim.2025.3583294
- Citations
- 1
- Primary Topic
- Air Quality Monitoring and Forecasting
- Type
- article
- Field-Weighted Citation Impact
- 0.80