Influences of Human Presence on the Indoor Air Quality of Educational Institutions: Concurrent Multipollutant Sensing Approach

This study evaluates how human presence influences classroom air quality using an edge-intelligent, low-cost monitoring system (AQMS) that senses multiple pollutants and quantifies occupancy with an on-board camera and custom object-detection model. Over seven days in a laboratory, we varied air-conditioning and ventilation settings while the AQMS logged pollutant levels every minute. Spearman rank-order analysis showed strong positive correlations between occupancy and CO2, total VOCs, and gas-sensor resistance, but no significant link with CO, NH3, or NO2. Particulate matter (PM2.5, PM10) briefly fell as occupancy rose, yet this trend vanished when air-conditioning was active, indicating its filtration effect. Rooms without air-conditioning but with adequate ventilation maintained lower CO2 and VOC levels. PM findings were inconclusive because of concurrent inhalation effects. All occupancy data were privacy-preserving—images were processed on device and never stored. Although demonstrated in a single room, the architecture is inherently scalable, and a multi-room urban–rural deployment is underway.

Authors

Institutions

Publication Details

Journal
IEEE Open Journal of Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/ojim.2025.3583294
Citations
1
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influences of Human Presence on the Indoor Air Quality of Educational Institutions: Concurrent Multipollutant Sensing Approach

Shubhankar Majumdar, Aritra Acharyya, Rajib Das
1 citations
IEEE Open Journal of Instrumentation and Measurement
Air Quality Monitoring and Forecasting
0.80
article

Influences of Human Presence on the Indoor Air Quality of Educational Institutions: Concurrent Multipollutant Sensing Approach

Shubhankar Majumdar, Aritra Acharyya, Rajib Das
article en
1 citations

Abstract

This study evaluates how human presence influences classroom air quality using an edge-intelligent, low-cost monitoring system (AQMS) that senses multiple pollutants and quantifies occupancy with an on-board camera and custom object-detection model. Over seven days in a laboratory, we varied air-conditioning and ventilation settings while the AQMS logged pollutant levels every minute. Spearman rank-order analysis showed strong positive correlations between occupancy and CO2, total VOCs, and gas-sensor resistance, but no significant link with CO, NH3, or NO2. Particulate matter (PM2.5, PM10) briefly fell as occupancy rose, yet this trend vanished when air-conditioning was active, indicating its filtration effect. Rooms without air-conditioning but with adequate ventilation maintained lower CO2 and VOC levels. PM findings were inconclusive because of concurrent inhalation effects. All occupancy data were privacy-preserving—images were processed on device and never stored. Although demonstrated in a single room, the architecture is inherently scalable, and a multi-room urban–rural deployment is underway.

IEEE Open Journal of Instrumentation and MeasurementVol. 4
Cooch Behar Panchanan Barma University (IN), University of Kalyani (IN), National Institute of Technology Meghalaya (IN)
Openalex Percentile: Top 28%
Air Quality Monitoring and Forecasting
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.