Highly sensitive and selective detection of KLK4 in human serum with a low-cost electrochemical biosensor

An ultrasensitive impedimetric immunosensor was fabricated using a poly(glycidyl methacrylate) (PGMA) polymer-covered indium tin oxide (ITO) platform for the quantification of kallikrein 4 (KLK4), an important prostate cancer biomarker. PGMA had suitable biocompatibility and nontoxicity for loading of antiKLK4 antibodies on the ITO substrate surface. Anti-KLK4 biomolecules were directly attached to the PGMA-covered electrode surface via epoxy groups of the PGMA polymer. The preparation method for the PGMA matrix-modified electrode was simple and inexpensive. The proposed biosensor immobilization layers coated on the ITO electrode were characterized with electrochemical techniques. The experimental parameters that affect biosensor response were optimized, and the suggested sensor showed a linear response from 0.04 pg/mL to 8 pg/mL with a low detection limit (LOD) of 12.21 fg/mL. Moreover, it had acceptable stability, reproducibility, and repeatability. Additionally, the disposable biosensor offered excellent reliability and accuracy in KLK4 analysis, suggesting that it could be used as an alternative technique in clinical diagnosis.

Authors

Institutions

Publication Details

Journal
TURKISH JOURNAL OF CHEMISTRY
Published
2025-06-24
DOI
https://doi.org/10.55730/1300-0527.3737
Citations
1
Primary Topic
Coagulation, Bradykinin, Polyphosphates, and Angioedema
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly sensitive and selective detection of KLK4 in human serum with a low-cost electrochemical biosensor

Elif Burcu Aydın
1 citations
TURKISH JOURNAL OF CHEMISTRY
Coagulation, Bradykinin, Polyphosphates, and Angioedema
1.63
article

Highly sensitive and selective detection of KLK4 in human serum with a low-cost electrochemical biosensor

Elif Burcu Aydın
article en
1 citations

Abstract

An ultrasensitive impedimetric immunosensor was fabricated using a poly(glycidyl methacrylate) (PGMA) polymer-covered indium tin oxide (ITO) platform for the quantification of kallikrein 4 (KLK4), an important prostate cancer biomarker. PGMA had suitable biocompatibility and nontoxicity for loading of antiKLK4 antibodies on the ITO substrate surface. Anti-KLK4 biomolecules were directly attached to the PGMA-covered electrode surface via epoxy groups of the PGMA polymer. The preparation method for the PGMA matrix-modified electrode was simple and inexpensive. The proposed biosensor immobilization layers coated on the ITO electrode were characterized with electrochemical techniques. The experimental parameters that affect biosensor response were optimized, and the suggested sensor showed a linear response from 0.04 pg/mL to 8 pg/mL with a low detection limit (LOD) of 12.21 fg/mL. Moreover, it had acceptable stability, reproducibility, and repeatability. Additionally, the disposable biosensor offered excellent reliability and accuracy in KLK4 analysis, suggesting that it could be used as an alternative technique in clinical diagnosis.

TURKISH JOURNAL OF CHEMISTRYVol. 49(3)
Tekirdağ Namık Kemal University (TR)
Affordable and clean energy
Openalex Percentile: Top 16%
Coagulation, Bradykinin, Polyphosphates, and Angioedema
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.