Seismic Performance Analysis of Replaceable Corrugated Steel Plate Composite Shear Walls Based on Interaction Relationships

Replaceable systems, including the main structure and components, are the primary means of building a resilient city. However, due to the complex interaction relationships, the energy‐dissipation effect of such structural systems is not ideal. Accordingly, this study used a replaceable corrugated steel plate composite shear wall as an example, focusing on the seismic performance and energy‐dissipation ratio analyses of each component. We attempted to find a suitable stiffness ratio index to determine the interaction relationship of the replaceable corrugated steel plate shear wall. An energy‐dissipation evaluation method is proposed based on the stiffness ratio index, and the bearing‐capacity formula of the shear wall was modified. The results show that the revised lateral‐bearing‐capacity formula based on the energy dissipation evaluation exhibited ideal accuracy and could provide a reference for practical engineering applications.

Authors

Institutions

Publication Details

Journal
Structural Control and Health Monitoring
Published
2025-01-01
DOI
https://doi.org/10.1155/stc/3576799
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Performance Analysis of Replaceable Corrugated Steel Plate Composite Shear Walls Based on Interaction Relationships

Shixing Zhao, Shuheng Yang, Qirui Luo, Wei Wang et al.
1 citations
Structural Control and Health Monitoring
Structural Load-Bearing Analysis
0.95
article

Seismic Performance Analysis of Replaceable Corrugated Steel Plate Composite Shear Walls Based on Interaction Relationships

Shixing Zhao, Shuheng Yang, Qirui Luo, Wei Wang, Min Zhang
article en
1 citations

Abstract

Replaceable systems, including the main structure and components, are the primary means of building a resilient city. However, due to the complex interaction relationships, the energy‐dissipation effect of such structural systems is not ideal. Accordingly, this study used a replaceable corrugated steel plate composite shear wall as an example, focusing on the seismic performance and energy‐dissipation ratio analyses of each component. We attempted to find a suitable stiffness ratio index to determine the interaction relationship of the replaceable corrugated steel plate shear wall. An energy‐dissipation evaluation method is proposed based on the stiffness ratio index, and the bearing‐capacity formula of the shear wall was modified. The results show that the revised lateral‐bearing‐capacity formula based on the energy dissipation evaluation exhibited ideal accuracy and could provide a reference for practical engineering applications.

Structural Control and Health MonitoringVol. 2025(1)
Xi'an University of Architecture and Technology (CN), Southwest Petroleum University (CN), Sichuan Provincial Architectural Design and Research Institute (China) (CN)
National Natural Science Foundation of China, Jiangsu Development and Reform Commission, Department of Science and Technology of Sichuan Province
Openalex Percentile: Top 24%
Structural Load-Bearing Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Seismic Performance Analysis of Replaceable Corrugated Steel Plate Composite Shear Walls Based on Interaction Relationships — Shixing Zhao, Shuheng Yang, et al. · Structural Control and Health Monitoring (2025) | TGRS Research Map | TGRS