COMPARISON OF EYE AXIAL LENGTH AMONG YOUNG AND OLD HEALTHY VOLUNTEERS MEASURED ON TRANSORBITAL ULTRASOUND

Background: Transorbital ultrasonography is a non-invasive, accessible, and effective imaging modality for ocular biometry, particularly valuable for measuring axial length—the distance from the anterior corneal surface to the inner retinal layer. Accurate axial length measurement is crucial for calculating intraocular lens (IOL) power, especially in cataract surgery. Establishing normative values across age groups is essential for both diagnostic accuracy and surgical outcomes in ophthalmic care. Objective: To compare the axial length of the eye between young and older healthy adult volunteers using transorbital ultrasonography. Methods: This comparative cross-sectional study was conducted from January to April 2025 at Fatima Medical Lab, Rahim Yar Khan. A total of 50 healthy participants (100 eyes), including 27 males (54%) and 23 females (46%), were recruited and divided into two age groups: Group 1 (20–40 years) and Group 2 (41–60 years), with 25 participants in each group. Eye axial length was measured using a 9–12 MHz linear transducer on a GE S6 ultrasound system. Each eye was scanned three times, and the average value was recorded. Data were analyzed using SPSS version 2025. Independent sample t-tests were applied, and p-values <0.05 were considered statistically significant. Results: The participants had a mean age of 38.92 ± 11.22 years. The overall mean right eye axial length was 23.05 ± 1.4 mm, and the left eye axial length was 23.06 ± 1.6 mm. In Group 1, the right eye axial length averaged 23.40 ± 1.2 mm compared to 22.80 ± 1.3 mm in Group 2 (p = 0.121). The left eye measurements were 24.09 ± 1.0 mm and 23.90 ± 1.2 mm for Groups 1 and 2, respectively (p = 0.558), indicating no statistically significant difference. Conclusion: This study demonstrates that axial length, as measured by transorbital ultrasonography, shows no significant variation between young and older healthy adults, suggesting it remains relatively stable across adulthood in the absence of ocular or systemic pathology.

Authors

Institutions

Publication Details

Journal
Insights-Journal of Health and Rehabilitation
Published
2025-06-20
DOI
https://doi.org/10.71000/kfn92n42
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMPARISON OF EYE AXIAL LENGTH AMONG YOUNG AND OLD HEALTHY VOLUNTEERS MEASURED ON TRANSORBITAL ULTRASOUND

Ayesha Shahid, Saba Ajmal, Shaista Bibi, Kashif Irshad et al.
Insights-Journal of Health and Rehabilitation
Ophthalmology and Visual Impairment Studies
article

COMPARISON OF EYE AXIAL LENGTH AMONG YOUNG AND OLD HEALTHY VOLUNTEERS MEASURED ON TRANSORBITAL ULTRASOUND

Ayesha Shahid, Saba Ajmal, Shaista Bibi, Kashif Irshad, Asif Naeem, Muhammad Tufail, Maria Yaseen, A. Bilal, Aks-E-Qamar
article en

Abstract

Background: Transorbital ultrasonography is a non-invasive, accessible, and effective imaging modality for ocular biometry, particularly valuable for measuring axial length—the distance from the anterior corneal surface to the inner retinal layer. Accurate axial length measurement is crucial for calculating intraocular lens (IOL) power, especially in cataract surgery. Establishing normative values across age groups is essential for both diagnostic accuracy and surgical outcomes in ophthalmic care. Objective: To compare the axial length of the eye between young and older healthy adult volunteers using transorbital ultrasonography. Methods: This comparative cross-sectional study was conducted from January to April 2025 at Fatima Medical Lab, Rahim Yar Khan. A total of 50 healthy participants (100 eyes), including 27 males (54%) and 23 females (46%), were recruited and divided into two age groups: Group 1 (20–40 years) and Group 2 (41–60 years), with 25 participants in each group. Eye axial length was measured using a 9–12 MHz linear transducer on a GE S6 ultrasound system. Each eye was scanned three times, and the average value was recorded. Data were analyzed using SPSS version 2025. Independent sample t-tests were applied, and p-values <0.05 were considered statistically significant. Results: The participants had a mean age of 38.92 ± 11.22 years. The overall mean right eye axial length was 23.05 ± 1.4 mm, and the left eye axial length was 23.06 ± 1.6 mm. In Group 1, the right eye axial length averaged 23.40 ± 1.2 mm compared to 22.80 ± 1.3 mm in Group 2 (p = 0.121). The left eye measurements were 24.09 ± 1.0 mm and 23.90 ± 1.2 mm for Groups 1 and 2, respectively (p = 0.558), indicating no statistically significant difference. Conclusion: This study demonstrates that axial length, as measured by transorbital ultrasonography, shows no significant variation between young and older healthy adults, suggesting it remains relatively stable across adulthood in the absence of ocular or systemic pathology.

Insights-Journal of Health and RehabilitationVol. 3(3 (Health & Allied))
Khwaja Fareed University of Engineering and Information Technology (PK)
Openalex Percentile: Top 79%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.