Ab Interno Occlusion of Ahmed Glaucoma Valve Tube with a 4–0 Polypropylene Suture in a Patient with Hypotony

The objective is to present the clinical improvement observed after ab interno intraluminal occlusion of Ahmed glaucoma valve (AGV) tube with a 4-0 polypropylene suture in a patient with secondary hypotony following AGV implantation. A 47-year-old male patient with a history of retinitis pigmentosa, congenital cataract, and glaucoma had undergone ex-press glaucoma filtration device implantation and cyclophotocoagulation treatments in his left eye previously. The intraocular pressure (IOP) was not regulated with these treatments, and an AGV implantation was performed in our clinic. Due to the development of hypotony at the postoperative 1st week, ab interno intraluminal occlusion of the AGV tube was planned with a 4-0 polypropylene suture. Before AGV tube implantation, the best-corrected visual acuity (BCVA) was 0.05, and IOP was 40 mmHg (with maximum antiglaucoma medication) in the left eye of the patient. At the postoperative 1st week, BCVA regressed to the level of hand motion, and IOP was <5 mmHg. Findings such as corneal fold, hypotony maculopathy, and choroidal effusion were also observed. Since there was no response to anti-inflammatory medical treatment initiated to reduce hypotony, ab interno intraluminal occlusion of the AGV tube was performed. After revision surgery, it was observed that IOP increased to 10 mmHg and BCVA increased to 0.1. In cases with postoperative hypotony due to excessive filtration after glaucoma drainage device implantation, ab interno occlusion of the tube lumen with a 4-0 polypropylene suture is an effective, safe, and inexpensive alternative surgical method that can be performed without causing conjunctival damage or subconjunctival scarring.

Authors

Institutions

Publication Details

Journal
Beyoglu Eye Journal
Published
2025-01-01
DOI
https://doi.org/10.14744/bej.2025.56667
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ab Interno Occlusion of Ahmed Glaucoma Valve Tube with a 4–0 Polypropylene Suture in a Patient with Hypotony

İskender Kara
Beyoglu Eye Journal
Glaucoma and retinal disorders
article

Ab Interno Occlusion of Ahmed Glaucoma Valve Tube with a 4–0 Polypropylene Suture in a Patient with Hypotony

İskender Kara
article en

Abstract

The objective is to present the clinical improvement observed after ab interno intraluminal occlusion of Ahmed glaucoma valve (AGV) tube with a 4-0 polypropylene suture in a patient with secondary hypotony following AGV implantation. A 47-year-old male patient with a history of retinitis pigmentosa, congenital cataract, and glaucoma had undergone ex-press glaucoma filtration device implantation and cyclophotocoagulation treatments in his left eye previously. The intraocular pressure (IOP) was not regulated with these treatments, and an AGV implantation was performed in our clinic. Due to the development of hypotony at the postoperative 1st week, ab interno intraluminal occlusion of the AGV tube was planned with a 4-0 polypropylene suture. Before AGV tube implantation, the best-corrected visual acuity (BCVA) was 0.05, and IOP was 40 mmHg (with maximum antiglaucoma medication) in the left eye of the patient. At the postoperative 1st week, BCVA regressed to the level of hand motion, and IOP was <5 mmHg. Findings such as corneal fold, hypotony maculopathy, and choroidal effusion were also observed. Since there was no response to anti-inflammatory medical treatment initiated to reduce hypotony, ab interno intraluminal occlusion of the AGV tube was performed. After revision surgery, it was observed that IOP increased to 10 mmHg and BCVA increased to 0.1. In cases with postoperative hypotony due to excessive filtration after glaucoma drainage device implantation, ab interno occlusion of the tube lumen with a 4-0 polypropylene suture is an effective, safe, and inexpensive alternative surgical method that can be performed without causing conjunctival damage or subconjunctival scarring.

Beyoglu Eye JournalVol. 10(2)
Necmettin Erbakan University (TR)
Zero hunger
Openalex Percentile: Top 77%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.