Multi-marker Similarity Enables Reduced-Reference and Interpretable Image Quality Assessment in Optical Microscopy

Optical microscopy contributes to the ever-increasing progress in biological and biomedical studies, as it allows the implementation of minimally invasive experimental pipelines to translate the data of measured samples into valuable knowledge. Within these pipelines, reliable quality assessment must be ensured to validate the generated results. Image quality assessment is often applied with full-reference methods to estimate the similarity between the ground truth and the output images. However, current methods often show poor agreement with visual perception and lead to the generation of various full-reference metrics tailored to specific applications. Additionally, they rely on pixel-wise comparisons, emphasizing local intensity similarity while often overlooking comprehensive and interpretable image quality assessment. To address these issues, we have developed a multi-marker similarity method that compares standard quality markers, such as resolution, signal-to-noise ratio, contrast, and high-frequency components. The method computes a similarity score between the image and the ground truth for each marker and then combines these scores into an overall similarity estimate. This provides a full-reference estimate of image quality while extracting global quality features and detecting experimental artifacts. Multi-marker similarity provides a reliable and interpretable method for image quality assessment and the generation of quality rankings. By focusing on the comparison of quality markers rather than direct image distances, the method enables reduced-reference implementations, where a single field of view is used as a benchmark for multiple measurements. This opens a way for reliable automatic evaluation of big datasets, typical of large biomedical studies, when manually assessing single images and defining the ground truth for each field of view is not feasible.

Authors

Institutions

Publication Details

Journal
Research
Published
2025-01-01
DOI
https://doi.org/10.34133/research.0783
Citations
4
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
9.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-marker Similarity Enables Reduced-Reference and Interpretable Image Quality Assessment in Optical Microscopy

Thomas Wilhelm Bocklitz, Elena Corbetta
4 citations
Research
AI in cancer detection
9.92
article

Multi-marker Similarity Enables Reduced-Reference and Interpretable Image Quality Assessment in Optical Microscopy

Thomas Wilhelm Bocklitz, Elena Corbetta
article en
4 citations

Abstract

Optical microscopy contributes to the ever-increasing progress in biological and biomedical studies, as it allows the implementation of minimally invasive experimental pipelines to translate the data of measured samples into valuable knowledge. Within these pipelines, reliable quality assessment must be ensured to validate the generated results. Image quality assessment is often applied with full-reference methods to estimate the similarity between the ground truth and the output images. However, current methods often show poor agreement with visual perception and lead to the generation of various full-reference metrics tailored to specific applications. Additionally, they rely on pixel-wise comparisons, emphasizing local intensity similarity while often overlooking comprehensive and interpretable image quality assessment. To address these issues, we have developed a multi-marker similarity method that compares standard quality markers, such as resolution, signal-to-noise ratio, contrast, and high-frequency components. The method computes a similarity score between the image and the ground truth for each marker and then combines these scores into an overall similarity estimate. This provides a full-reference estimate of image quality while extracting global quality features and detecting experimental artifacts. Multi-marker similarity provides a reliable and interpretable method for image quality assessment and the generation of quality rankings. By focusing on the comparison of quality markers rather than direct image distances, the method enables reduced-reference implementations, where a single field of view is used as a benchmark for multiple measurements. This opens a way for reliable automatic evaluation of big datasets, typical of large biomedical studies, when manually assessing single images and defining the ground truth for each field of view is not feasible.

ResearchVol. 8
Leibniz Institute of Photonic Technology (DE), Friedrich Schiller University Jena (DE)
Openalex Percentile: Top 2%
AI in cancer detection
9.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.