The X-ray class of the Carrington flare

ABSTRACT The geomagnetic ‘solar flare effect’ (SFE) results from excess ionization produced by solar X-ray and EUV radiation in the Earth’s upper atmosphere. The simultaneous detection of an SFE at the time of the Carrington flare in 1859 allows us to calibrate this event on the (revised) modern GOES X-ray scale. For this purpose, we make a basic correlation analysis of SFEs recorded at 1-min averaging at a single geomagnetic observatory, the Hartland station, as the site closest to London and the two original observing stations (Kew and Greenwich). We find the equivalent GOES magnitude of the Carrington event to have been X105$^{+41,-24}$ based on a sample of 39 X-class flare events observable as SFEs, with the estimate limited by systematic errors in the interpretation of the modern data. This estimate agrees with estimates based on the visual observations of the flare. This suggests that the Carrington flare was not a ‘superflare’ in the sense that it required physics beyond that needed for ordinary flares.

Authors

Institutions

Publication Details

Journal
Monthly Notices of the Royal Astronomical Society
Published
2025-06-24
DOI
https://doi.org/10.1093/mnras/staf967
Primary Topic
Solar and Space Plasma Dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The X-ray class of the Carrington flare

Ciarán Beggan, Hugh S. Hudson, Christopher M. J. Osborne, P. T. Gallagher et al.
1 links
Monthly Notices of the Royal Astronomical Society
Solar and Space Plasma Dynamics
article

The X-ray class of the Carrington flare

Ciarán Beggan, Hugh S. Hudson, Christopher M. J. Osborne, P. T. Gallagher, G. Woan, E. W. Cliver, Hisashi Hayakawa, Ellen Clarke
article en

Abstract

ABSTRACT The geomagnetic ‘solar flare effect’ (SFE) results from excess ionization produced by solar X-ray and EUV radiation in the Earth’s upper atmosphere. The simultaneous detection of an SFE at the time of the Carrington flare in 1859 allows us to calibrate this event on the (revised) modern GOES X-ray scale. For this purpose, we make a basic correlation analysis of SFEs recorded at 1-min averaging at a single geomagnetic observatory, the Hartland station, as the site closest to London and the two original observing stations (Kew and Greenwich). We find the equivalent GOES magnitude of the Carrington event to have been X105$^{+41,-24}$ based on a sample of 39 X-class flare events observable as SFEs, with the estimate limited by systematic errors in the interpretation of the modern data. This estimate agrees with estimates based on the visual observations of the flare. This suggests that the Carrington flare was not a ‘superflare’ in the sense that it required physics beyond that needed for ordinary flares.

Monthly Notices of the Royal Astronomical SocietyVol. 544(2)
Dublin Institute For Advanced Studies (IE), British Geological Survey (GB), National Solar Observatory (US), Nagoya University (JP), University of Glasgow (GB), University of California, Berkeley (US)
University of Glasgow, Ministry of Education, Culture, Sports, Science and Technology, Japan Society for the Promotion of Science
Openalex Percentile: Top 90%
Solar and Space Plasma Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The X-ray class of the Carrington flare — Ciarán Beggan, Hugh S. Hudson, et al. · Monthly Notices of the Royal Astronomical Society (2025) | TGRS Research Map | TGRS