Next-Gen Non-Invasive Glucose Monitoring Using Microwave Sensors and AI-Based Thumb Positioning Analysis

Because of discomfort and accuracy problems, the existing non-invasive glucose monitoring devices include optical sensors and finger-prick tests have long been under doubt for their viability. Variations in skin type and environmental interference might make these techniques unreliable. To get past these constraints, the study presents a fresh approach combining artificial intelligence (AI)-based thumb positioning analysis with microwave sensors. By spotting changes in the dielectric characteristics of the skin brought on by glucose, the microwave sensors offer exact, invasive, real-time readings. Through best sensor alignment, AI removes thumb position errors. Performance assessment indicates substantially better outcomes than the existing systems with an R2 of 0.98, RMSE of 7.1 mg/dL, and MAE of 5.2 mg/dL. The great flexibility of the proposed system to a wide spectrum of demographics and excellent user compliance (95%) underlines its possibility for efficient and comfortable diabetes control. The technique represents a substantial development in non-invasive glucose monitoring.

Authors

Institutions

Publication Details

Published
2025-05-07
DOI
https://doi.org/10.1109/rmkmate64874.2025.11042731
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Next-Gen Non-Invasive Glucose Monitoring Using Microwave Sensors and AI-Based Thumb Positioning Analysis

Guma Ali, D. Elumalai, Beulah Jackson, P. Soundharya et al.
Wireless Body Area Networks
article

Next-Gen Non-Invasive Glucose Monitoring Using Microwave Sensors and AI-Based Thumb Positioning Analysis

Guma Ali, D. Elumalai, Beulah Jackson, P. Soundharya, S. Charisma, G. Ganapathi
article en

Abstract

Because of discomfort and accuracy problems, the existing non-invasive glucose monitoring devices include optical sensors and finger-prick tests have long been under doubt for their viability. Variations in skin type and environmental interference might make these techniques unreliable. To get past these constraints, the study presents a fresh approach combining artificial intelligence (AI)-based thumb positioning analysis with microwave sensors. By spotting changes in the dielectric characteristics of the skin brought on by glucose, the microwave sensors offer exact, invasive, real-time readings. Through best sensor alignment, AI removes thumb position errors. Performance assessment indicates substantially better outcomes than the existing systems with an R2 of 0.98, RMSE of 7.1 mg/dL, and MAE of 5.2 mg/dL. The great flexibility of the proposed system to a wide spectrum of demographics and excellent user compliance (95%) underlines its possibility for efficient and comfortable diabetes control. The technique represents a substantial development in non-invasive glucose monitoring.

Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology (IN), Dr. M.G.R. Educational and Research Institute (IN), St. Joseph's Institute of Technology (IN), Dhanalakshmi Srinivasan Group of Institutions (IN), R.M.D. Engineering College, Saveetha University (IN)
Zero hunger
Openalex Percentile: Top 86%
Wireless Body Area Networks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.