Comparison of perch deflection, conductor separation and insulation methods at reducing avian electrocutions at an electricity distribution line in Mongolia

Abstract We report persistent high rates of raptor electrocution, particularly of Saker Falcons (Falco cherrug) , in the Mongolian steppe grasslands. In 2018–2019, we conducted a trial to compare the efficacy of five mitigation techniques to reduce avian electrocutions at a 15 kV 3-phase power distribution line in Mongolia with a history of consistently high electrocution rates. All five techniques significantly reduced electrocution rates in comparison to controls with no mitigation. At phase 1 on the pole top, we found no significant difference in the efficacy of conductor insulation, arch-type pin-insulator mounts and the use of two pin-insulators as a means of deflecting birds from dangerous perch sites. At phases 2 and 3 on the crossarm, we found no significant difference in the efficacy of conductor insulation and the use of suspended insulators. We discuss the utility of insulation methods and pole hardware reconfiguration for retrospective mitigation of dangerous power poles that pose an avian electrocution risk.

Authors

Institutions

Publication Details

Journal
Ornis Hungarica
Published
2025-05-15
DOI
https://doi.org/10.2478/orhu-2025-0013
Primary Topic
Fire effects on ecosystems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of perch deflection, conductor separation and insulation methods at reducing avian electrocutions at an electricity distribution line in Mongolia

Amarkhuu Gungaa, Makhgal Ganbold, Nyambayar Batbayar, Purevsuren Tsolmonjav et al.
Ornis Hungarica
Fire effects on ecosystems
article

Comparison of perch deflection, conductor separation and insulation methods at reducing avian electrocutions at an electricity distribution line in Mongolia

Amarkhuu Gungaa, Makhgal Ganbold, Nyambayar Batbayar, Purevsuren Tsolmonjav, Gankhuyag Purev-Ochir, Batbayar Bold, Andrew Dixon
article en

Abstract

Abstract We report persistent high rates of raptor electrocution, particularly of Saker Falcons (Falco cherrug) , in the Mongolian steppe grasslands. In 2018–2019, we conducted a trial to compare the efficacy of five mitigation techniques to reduce avian electrocutions at a 15 kV 3-phase power distribution line in Mongolia with a history of consistently high electrocution rates. All five techniques significantly reduced electrocution rates in comparison to controls with no mitigation. At phase 1 on the pole top, we found no significant difference in the efficacy of conductor insulation, arch-type pin-insulator mounts and the use of two pin-insulators as a means of deflecting birds from dangerous perch sites. At phases 2 and 3 on the crossarm, we found no significant difference in the efficacy of conductor insulation and the use of suspended insulators. We discuss the utility of insulation methods and pole hardware reconfiguration for retrospective mitigation of dangerous power poles that pose an avian electrocution risk.

Ornis HungaricaVol. 33(1)
Mongolian University of Life Sciences (MN), Mohamed Bin Zayed Species Conservation Fund (AE), Wildlife Science Center (US), National University of Mongolia (MN)
Openalex Percentile: Top 86%
Fire effects on ecosystems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.