Performance and diagnostic of guided wave PZT transducers under reusable launch vehicles thermal flight conditions

This paper examines the impact of brief but intense thermal cycling on surface-bonded guided waves (GW) piezoelectric transducers (PZT). The effects on both electromechanical impedance (EMI) self-diagnostic measurements and Lamb wave emission and reception performance are investigated through experimental and numerical studies. EMI spectra are acquired in the 80–400 kHz range with both the real and imaginary parts being studied. GW pitch-catch measurements are conducted for two frequency ranges (15–25 kHz and 150–250 kHz) to investigate the two fundamental Lamb wave modes. Furthermore, laser Doppler vibrometry (LDV) scans are performed to detect and localize transducer debondings. A finite element model of a surface bonded PZT is used to reproduce qualitatively both pitch-catch measurements and EMI spectrum in order to test the impact of different parameters and to support the interpretation of the test results. Two types of evolution with thermal cycling have been identified, each with distinct EMI and GW signatures. Firstly, the PZTs show a uniform 15%–20% reduction in GW sensing capabilities across the studied frequency range, with unchanged emission capabilities. This behavior is associated with irreversible effects of the thermal cycling on the constitutive properties of the PZT (mainly on the relative permittivity) and, to a lesser extent, to the evolution of the mechanical properties of the bonding layer. Secondly, a unique signature of partial PZT debondings is exhibited on the EMI spectra and LDV scans. The debonding has little impact on the GW signals at low frequency but results in amplitude changes and phase delays of both the received and emitted waveforms in the higher frequency range.

Authors

Institutions

Publication Details

Journal
Journal of Intelligent Material Systems and Structures
Published
2025-06-25
DOI
https://doi.org/10.1177/1045389x251346334
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and diagnostic of guided wave PZT transducers under reusable launch vehicles thermal flight conditions

Jean-Michel Roche, J. N. Eiras, Ludovic Gavérina, François-Xavier Irisarri et al.
Journal of Intelligent Material Systems and Structures
Ultrasonics and Acoustic Wave Propagation
article

Performance and diagnostic of guided wave PZT transducers under reusable launch vehicles thermal flight conditions

Jean-Michel Roche, J. N. Eiras, Ludovic Gavérina, François-Xavier Irisarri, Loïc Mastromatteo, Florian Lavelle
article en

Abstract

This paper examines the impact of brief but intense thermal cycling on surface-bonded guided waves (GW) piezoelectric transducers (PZT). The effects on both electromechanical impedance (EMI) self-diagnostic measurements and Lamb wave emission and reception performance are investigated through experimental and numerical studies. EMI spectra are acquired in the 80–400 kHz range with both the real and imaginary parts being studied. GW pitch-catch measurements are conducted for two frequency ranges (15–25 kHz and 150–250 kHz) to investigate the two fundamental Lamb wave modes. Furthermore, laser Doppler vibrometry (LDV) scans are performed to detect and localize transducer debondings. A finite element model of a surface bonded PZT is used to reproduce qualitatively both pitch-catch measurements and EMI spectrum in order to test the impact of different parameters and to support the interpretation of the test results. Two types of evolution with thermal cycling have been identified, each with distinct EMI and GW signatures. Firstly, the PZTs show a uniform 15%–20% reduction in GW sensing capabilities across the studied frequency range, with unchanged emission capabilities. This behavior is associated with irreversible effects of the thermal cycling on the constitutive properties of the PZT (mainly on the relative permittivity) and, to a lesser extent, to the evolution of the mechanical properties of the bonding layer. Secondly, a unique signature of partial PZT debondings is exhibited on the EMI spectra and LDV scans. The debonding has little impact on the GW signals at low frequency but results in amplitude changes and phase delays of both the received and emitted waveforms in the higher frequency range.

Journal of Intelligent Material Systems and StructuresVol. 36(12)
Université Paris-Saclay (FR), Centre National d'Études Spatiales (FR), Office National d'Études et de Recherches Aérospatiales (FR)
Openalex Percentile: Top 84%
Ultrasonics and Acoustic Wave Propagation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.