Frequency-Dependent Effects of Pulsatile Flow on Particle Inertial Focusing and Separation in Sinusoidal Microchannels

Inertial microfluidics leverages hydrodynamic forces to manipulate and separate particles at high flow speeds. Benefiting from its simplicity, high throughput, and accurate manipulation, inertial microfluidics has been extensively studied for processing particle and cellular samples. Most research in the field has focused on steady flows, where the flow speed and direction are constant. In real-world applications, pumping systems are never perfect and often experience flow variations due to device vibration, tubing compliance, or pressure fluctuations. Understanding the influence of flow pulsation on particle inertial focusing and separation is of great importance. Therefore, this work investigates the effects of flow pulsation on inertial focusing and separation in a sinusoidal microchannel. First, we analyzed the dynamic characteristics of the microfluidic system using a hydraulic-electric analogy and determined the critical frequency of the system (<i>f</i><sub>c</sub>) as ∼9 Hz. Next, we experimentally investigated the effects of pulsatile flows on the inertial focusing of microparticles and compared them with steady flows. Additionally, the effects of pulsation amplitude and frequency were studied, and the particle distribution in the time domain was also examined. Finally, we evaluated the influence of flow pulsation on the separation of a binary particle mixture. While particle focusing and separation remained stable at pulsation frequencies above the critical frequency of the system, they were negatively affected at lower frequencies. At 5 Hz, the purity decreased notably for 15 μm particles (from 94% to 71%) and slightly for 10 μm particles (from 99% to 94%), while at 10 Hz, purities remained close to the steady flow values. The results showed that the pulsation frequency was a more critical parameter than the pulsation amplitude for particle inertial focusing and separation performance.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-06-25
DOI
https://doi.org/10.1021/acs.analchem.5c02367
Citations
3
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency-Dependent Effects of Pulsatile Flow on Particle Inertial Focusing and Separation in Sinusoidal Microchannels

Nam‐Trung Nguyen, Haotian Cha, Tuan‐Khoa Nguyen, Amith Mudugamuwa et al.
3 citations
Analytical Chemistry
Microfluidic and Bio-sensing Technologies
2.02
article

Frequency-Dependent Effects of Pulsatile Flow on Particle Inertial Focusing and Separation in Sinusoidal Microchannels

Nam‐Trung Nguyen, Haotian Cha, Tuan‐Khoa Nguyen, Amith Mudugamuwa, Jun Zhang, Uditha Roshan
article en
3 citations

Abstract

Inertial microfluidics leverages hydrodynamic forces to manipulate and separate particles at high flow speeds. Benefiting from its simplicity, high throughput, and accurate manipulation, inertial microfluidics has been extensively studied for processing particle and cellular samples. Most research in the field has focused on steady flows, where the flow speed and direction are constant. In real-world applications, pumping systems are never perfect and often experience flow variations due to device vibration, tubing compliance, or pressure fluctuations. Understanding the influence of flow pulsation on particle inertial focusing and separation is of great importance. Therefore, this work investigates the effects of flow pulsation on inertial focusing and separation in a sinusoidal microchannel. First, we analyzed the dynamic characteristics of the microfluidic system using a hydraulic-electric analogy and determined the critical frequency of the system (<i>f</i><sub>c</sub>) as ∼9 Hz. Next, we experimentally investigated the effects of pulsatile flows on the inertial focusing of microparticles and compared them with steady flows. Additionally, the effects of pulsation amplitude and frequency were studied, and the particle distribution in the time domain was also examined. Finally, we evaluated the influence of flow pulsation on the separation of a binary particle mixture. While particle focusing and separation remained stable at pulsation frequencies above the critical frequency of the system, they were negatively affected at lower frequencies. At 5 Hz, the purity decreased notably for 15 μm particles (from 94% to 71%) and slightly for 10 μm particles (from 99% to 94%), while at 10 Hz, purities remained close to the steady flow values. The results showed that the pulsation frequency was a more critical parameter than the pulsation amplitude for particle inertial focusing and separation performance.

Analytical ChemistryVol. 97(26)
Griffith University (AU), Quantum (Australia) (AU)
Griffith University, Australian Research Council
Affordable and clean energy
Openalex Percentile: Top 13%
Microfluidic and Bio-sensing Technologies
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.