Development and Experimental Validation of a Non Invasive Blood Group Detection System

An individual's blood group consists of red blood cell antigens whose composition is determined by protein presence, antigen structure, and gene series. Persons aged above six months have significant anti-A and/or anti-B in their serum. During transplantation and transfusion, ABO blood group identification is the most essential factor. The conventional method involves drawing blood samples from patients, and the blood group is determined based on the antigen-antibody reaction. This method consists of adding chemical reagents. However, this requires time of operation, and throughput analysis is high, and the process is also challenging to interpret. Accurate and rapid identification of blood groups is therefore crucial in various medical fields, including blood transfusions, organ transplants, and prenatal care. Traditional methods for blood typing often require extensive laboratory equipment and trained personnel, leading to delays and potential errors in critical situations. This research focuses on developing a non-invasive, compact, and user-friendly device capable of determining blood groups quickly without invasively collecting patient’s blood samples and using reagents. The system learns from a database of annotated blood samples by employing machine learning algorithms, enhancing its accuracy and reliability over time. A non invasive blood group detection system was verified experimentally on a laboratory prototype, achieving an accuracy of 95.9% in identifying blood groups and rhesus factors. Furthermore, a comparative analysis was conducted between the proposed system and existing counterparts. This analysis demonstrated that the proposed system outperforms others in accuracy, indicating the rhesus factor.

Authors

Publication Details

Journal
Tanzania Journal of Engineering and Technology
Published
2025-06-20
DOI
https://doi.org/10.52339/tjet.v44i1.1267
Primary Topic
Blood groups and transfusion
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Experimental Validation of a Non Invasive Blood Group Detection System

Nurath Kanule Nurudini, Almachius Kahwa, Bakari M. M. Mwinyiwiwa
Tanzania Journal of Engineering and Technology
Blood groups and transfusion
article

Development and Experimental Validation of a Non Invasive Blood Group Detection System

Nurath Kanule Nurudini, Almachius Kahwa, Bakari M. M. Mwinyiwiwa
article en

Abstract

An individual's blood group consists of red blood cell antigens whose composition is determined by protein presence, antigen structure, and gene series. Persons aged above six months have significant anti-A and/or anti-B in their serum. During transplantation and transfusion, ABO blood group identification is the most essential factor. The conventional method involves drawing blood samples from patients, and the blood group is determined based on the antigen-antibody reaction. This method consists of adding chemical reagents. However, this requires time of operation, and throughput analysis is high, and the process is also challenging to interpret. Accurate and rapid identification of blood groups is therefore crucial in various medical fields, including blood transfusions, organ transplants, and prenatal care. Traditional methods for blood typing often require extensive laboratory equipment and trained personnel, leading to delays and potential errors in critical situations. This research focuses on developing a non-invasive, compact, and user-friendly device capable of determining blood groups quickly without invasively collecting patient’s blood samples and using reagents. The system learns from a database of annotated blood samples by employing machine learning algorithms, enhancing its accuracy and reliability over time. A non invasive blood group detection system was verified experimentally on a laboratory prototype, achieving an accuracy of 95.9% in identifying blood groups and rhesus factors. Furthermore, a comparative analysis was conducted between the proposed system and existing counterparts. This analysis demonstrated that the proposed system outperforms others in accuracy, indicating the rhesus factor.

Tanzania Journal of Engineering and TechnologyVol. 44(2)
Openalex Percentile: Top 81%
Blood groups and transfusion
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Experimental Validation of a Non Invasive Blood Group Detection System — Nurath Kanule Nurudini, Almachius Kahwa, et al. · Tanzania Journal of Engineering and Technology (2025) | TGRS Research Map | TGRS