Fire modelling of a glove box for use in a two-zone fire model

• Glove box fire experiments in a confined and mechanically ventilated enclosure. • Glove box fire modelling using a two-zone model. • Assessment of the fire model behaviour for a complex fire scenario. Accidental fires in nuclear fuel manufacturing and reprocessing plants can cause the glove box containment to rupture with a risk of dispersion of radioactive materials within the installation. Fire safety analyses require an assessment of the resulting radiological consequences to reinforce the appropriate prevention and protection measures in these installations. Since 2019, a research project named FIGARO aims at reducing the uncertainties related to the assessment of the airborne release fraction of plutonium involved in glove box fires. As part of this project, a semi-mechanistic model of glove box fire was developed and implemented in the two-zone code SYLVIA. Modelling glove box fires is a challenging task due to complex phenomena occurring in the glove box during its combustion. No theory has yet been put forward on how to model all aspects of the problem, even for simple, open atmosphere conditions. This model separates the combustion of the polycarbonate containment walls of the glove box from that of the biological protection panels, by modelling a glove box as a set of horizontal and vertical walls. A validation of this model was performed on two large-scale glove box fire tests carried out in a confined and mechanically ventilated enclosure (BAG_CSS experiments). Note that some parameters of the glove box model have been calibrated on the glove box qualification test carried out in an open atmosphere, under a calorimetric hood. Considering this preliminary calibration, the fire heat release rate is well reproduced by the model for both experiments.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Design
Published
2025-06-24
DOI
https://doi.org/10.1016/j.nucengdes.2025.114256
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fire modelling of a glove box for use in a two-zone fire model

M. Coutin, J.P. Joret, François Lamare, W. Plumecocq
Nuclear Engineering and Design
Fire dynamics and safety research
article

Fire modelling of a glove box for use in a two-zone fire model

M. Coutin, J.P. Joret, François Lamare, W. Plumecocq
article en

Abstract

• Glove box fire experiments in a confined and mechanically ventilated enclosure. • Glove box fire modelling using a two-zone model. • Assessment of the fire model behaviour for a complex fire scenario. Accidental fires in nuclear fuel manufacturing and reprocessing plants can cause the glove box containment to rupture with a risk of dispersion of radioactive materials within the installation. Fire safety analyses require an assessment of the resulting radiological consequences to reinforce the appropriate prevention and protection measures in these installations. Since 2019, a research project named FIGARO aims at reducing the uncertainties related to the assessment of the airborne release fraction of plutonium involved in glove box fires. As part of this project, a semi-mechanistic model of glove box fire was developed and implemented in the two-zone code SYLVIA. Modelling glove box fires is a challenging task due to complex phenomena occurring in the glove box during its combustion. No theory has yet been put forward on how to model all aspects of the problem, even for simple, open atmosphere conditions. This model separates the combustion of the polycarbonate containment walls of the glove box from that of the biological protection panels, by modelling a glove box as a set of horizontal and vertical walls. A validation of this model was performed on two large-scale glove box fire tests carried out in a confined and mechanically ventilated enclosure (BAG_CSS experiments). Note that some parameters of the glove box model have been calibrated on the glove box qualification test carried out in an open atmosphere, under a calorimetric hood. Considering this preliminary calibration, the fire heat release rate is well reproduced by the model for both experiments.

Nuclear Engineering and DesignVol. 442
Institut de Radioprotection et de Sûreté Nucléaire (FR), Autorité de sûreté nucléaire et de radioprotection (FR)
Nuclear Regulation Authority
Sustainable cities and communities
Openalex Percentile: Top 83%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.