Modeling the Impact of Viscosity on Fricke Gel Dosimeter Radiolysis: A Radiation Chemical Simulation Approach

The Fricke gel dosimeter, a hydrogel-based chemical dosimeter containing dissolved ferrous sulfate, measures 3D radiation dose distributions by oxidizing Fe<sup>2+</sup> to Fe<sup>3+</sup> upon irradiation. This study investigates the variation in Fricke yield, <i>G</i>(Fe<sup>3+</sup>), from a radiation-chemical perspective in both standard and gel-like Fricke systems of varying viscosities, under low- and high-linear energy transfer (LET) conditions. We employed our Monte Carlo track chemistry code IONLYS-IRT, using protons of 300 MeV (LET~0.3 keV/µm) and 1 MeV (LET~25 keV/µm) as radiation sources. To assess the impact of viscosity on <i>G</i>(Fe<sup>3+</sup>), we systematically varied the diffusion coefficients of all radiolytic species in the Fricke gel, including Fe<sup>2+</sup> and Fe<sup>3+</sup> ions. Increasing gel viscosity reduces Fe<sup>3+</sup> diffusion and stabilizes spatial dose distributions but also lowers <i>G</i>(Fe<sup>3+</sup>), compromising measurement accuracy and sensitivity-especially under high-LET irradiation. Our results show that an optimal Fricke gel dosimeter must balance these competing factors. Simulations with lower sulfuric acid concentrations (e.g., 0.05 M vs. 0.4 M) further revealed that <i>G</i>(Fe<sup>3+</sup>) values at ~100 s are nearly identical for both low- and high-LET conditions. This study underscores the utility of Monte Carlo simulations in modeling viscosity effects on Fricke gel radiolysis, guiding dosimeter optimization to maximize sensitivity and accuracy while preserving spatial dose distribution integrity.

Authors

Institutions

Publication Details

Journal
Gels
Published
2025-06-24
DOI
https://doi.org/10.3390/gels11070489
Citations
1
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling the Impact of Viscosity on Fricke Gel Dosimeter Radiolysis: A Radiation Chemical Simulation Approach

Jintana Meesungnoen, Jean‐Paul Jay‐Gerin, Sumaiya Akhter Ria
1 citations
Gels
Radiation Therapy and Dosimetry
1.52
article

Modeling the Impact of Viscosity on Fricke Gel Dosimeter Radiolysis: A Radiation Chemical Simulation Approach

Jintana Meesungnoen, Jean‐Paul Jay‐Gerin, Sumaiya Akhter Ria
article en
1 citations

Abstract

The Fricke gel dosimeter, a hydrogel-based chemical dosimeter containing dissolved ferrous sulfate, measures 3D radiation dose distributions by oxidizing Fe<sup>2+</sup> to Fe<sup>3+</sup> upon irradiation. This study investigates the variation in Fricke yield, <i>G</i>(Fe<sup>3+</sup>), from a radiation-chemical perspective in both standard and gel-like Fricke systems of varying viscosities, under low- and high-linear energy transfer (LET) conditions. We employed our Monte Carlo track chemistry code IONLYS-IRT, using protons of 300 MeV (LET~0.3 keV/µm) and 1 MeV (LET~25 keV/µm) as radiation sources. To assess the impact of viscosity on <i>G</i>(Fe<sup>3+</sup>), we systematically varied the diffusion coefficients of all radiolytic species in the Fricke gel, including Fe<sup>2+</sup> and Fe<sup>3+</sup> ions. Increasing gel viscosity reduces Fe<sup>3+</sup> diffusion and stabilizes spatial dose distributions but also lowers <i>G</i>(Fe<sup>3+</sup>), compromising measurement accuracy and sensitivity-especially under high-LET irradiation. Our results show that an optimal Fricke gel dosimeter must balance these competing factors. Simulations with lower sulfuric acid concentrations (e.g., 0.05 M vs. 0.4 M) further revealed that <i>G</i>(Fe<sup>3+</sup>) values at ~100 s are nearly identical for both low- and high-LET conditions. This study underscores the utility of Monte Carlo simulations in modeling viscosity effects on Fricke gel radiolysis, guiding dosimeter optimization to maximize sensitivity and accuracy while preserving spatial dose distribution integrity.

GelsVol. 11(7)
Université de Sherbrooke (CA)
Université de Sherbrooke, Natural Sciences and Engineering Research Council of Canada
Affordable and clean energy
Openalex Percentile: Top 17%
Radiation Therapy and Dosimetry
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.