Correlation of HbA1c and Continuous Glucose Monitor Time in Range

<b>Background:</b> Current literature is limited to describing the correlation of continuous glucose monitor (CGM) use and improved HbA1cs in patients with type 2 diabetes. There is a lack of literature correlating HbA1c and time in range (TIR). In addition, data such as time spent with low or very low blood glucose levels are not assessed in existing literature. <b>Objective:</b> To assess the correlation between reduction of HbA1c and increase in TIR for patients using CGMs meeting with an interdisciplinary team. <b>Methods:</b> This retrospective chart review includes adult patients seen in an interdisciplinary internal medicine clinic consisting of a pharmacist and nurse practitioner. Data collection included patients with diabetes using CGMs for at least 3 months, who had a visit with the team in the last 12 months. Information collected included demographics, insurance, comorbidities, diabetes medications, HbA1c and CGM data at baseline and 3-month visit, and number of pharmacist medication interventions. Fisher's exact, chi-square, and Mann-Whitney <i>U</i> tests were used where appropriate. <b>Results:</b> HbA1c decreased from 8.6% to 7.5% 3 months later (<i>P</i> = 0.002). The average increase in TIR was 55.5% to 65.1% (<i>P</i> = 0.007). The overall decrease in HbA1c and increase in TIR had a high inverse correlation at baseline and 3 months (<i>r</i> = -0.7 and <i>r</i> = -0.7, <i>P</i> < 0.001). <b>Conclusion:</b> There is a strong inverse relationship between HbA1c and TIR, reduction in glucose variability with a slightly higher incidence time in low/very low following intervention. The type and frequency of pharmacist-initiated interventions support the clinical decision-making potential for pharmacotherapy adjustments.

Authors

Institutions

Publication Details

Journal
Journal of Pharmacy Technology
Published
2025-06-24
DOI
https://doi.org/10.1177/87551225251348832
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation of HbA1c and Continuous Glucose Monitor Time in Range

Alexander DeLucenay, Nabila Ahmed‐Sarwar, Hannah DePasquale
Journal of Pharmacy Technology
Diabetes Management and Research
article

Correlation of HbA1c and Continuous Glucose Monitor Time in Range

Alexander DeLucenay, Nabila Ahmed‐Sarwar, Hannah DePasquale
article en

Abstract

<b>Background:</b> Current literature is limited to describing the correlation of continuous glucose monitor (CGM) use and improved HbA1cs in patients with type 2 diabetes. There is a lack of literature correlating HbA1c and time in range (TIR). In addition, data such as time spent with low or very low blood glucose levels are not assessed in existing literature. <b>Objective:</b> To assess the correlation between reduction of HbA1c and increase in TIR for patients using CGMs meeting with an interdisciplinary team. <b>Methods:</b> This retrospective chart review includes adult patients seen in an interdisciplinary internal medicine clinic consisting of a pharmacist and nurse practitioner. Data collection included patients with diabetes using CGMs for at least 3 months, who had a visit with the team in the last 12 months. Information collected included demographics, insurance, comorbidities, diabetes medications, HbA1c and CGM data at baseline and 3-month visit, and number of pharmacist medication interventions. Fisher's exact, chi-square, and Mann-Whitney <i>U</i> tests were used where appropriate. <b>Results:</b> HbA1c decreased from 8.6% to 7.5% 3 months later (<i>P</i> = 0.002). The average increase in TIR was 55.5% to 65.1% (<i>P</i> = 0.007). The overall decrease in HbA1c and increase in TIR had a high inverse correlation at baseline and 3 months (<i>r</i> = -0.7 and <i>r</i> = -0.7, <i>P</i> < 0.001). <b>Conclusion:</b> There is a strong inverse relationship between HbA1c and TIR, reduction in glucose variability with a slightly higher incidence time in low/very low following intervention. The type and frequency of pharmacist-initiated interventions support the clinical decision-making potential for pharmacotherapy adjustments.

Journal of Pharmacy TechnologyVol. 41(5)
Unity Health System (US), St. John Fisher University (US)
Openalex Percentile: Top 78%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Correlation of HbA1c and Continuous Glucose Monitor Time in Range — Alexander DeLucenay, Nabila Ahmed‐Sarwar, et al. · Journal of Pharmacy Technology (2025) | TGRS Research Map | TGRS