Electric field estimation of 220kV and 400kV polymeric insulators using ANSYS-LF used in transmission lines

Polymeric insulators are important components in a power system network. Failure of a single polymeric insulator poses serious threat to reliability of electrical utilities. Polymeric insulator due to its organic nature, degrades when various stresses act on it. This degradation eventually cause flashover, shortening its service life span. The degradation expedites when they work under contaminated conditions. Electric field distribution analysis is critical to access the failure of an insulator. If electric field reaches a critical value, it may result in flashover and eventually failure of the insulator. The present work concentrates on modeling of 220kV and 400kV polymeric insulators using ANSYS-LF software. Electric field evaluation was carried out on these insulators with and without corona disc. Results indicate that with insertion of the corona disc, there is a decrease in E-field values at the triplen junction which is below the threshold value. This is the prime factor which inhibits the occurrence of flashover, thereby improving its service lifespan under contaminated conditions. Further practical scenarios such as bird pecking, brittle fracture are studied. The studies highlight sharp increase in electric field values due to reduction in creepage distance. These studies will help the design engineer to select the suitable profile of the insulator to suit harsh environment.

Authors

Institutions

Publication Details

Published
2024-08-10
DOI
https://doi.org/10.1109/iccccm61016.2024.11039884
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric field estimation of 220kV and 400kV polymeric insulators using ANSYS-LF used in transmission lines

Pradipkumar Dixit, Ramakrishna Murthy K, Vinayak V. Rao
High voltage insulation and dielectric phenomena
article

Electric field estimation of 220kV and 400kV polymeric insulators using ANSYS-LF used in transmission lines

Pradipkumar Dixit, Ramakrishna Murthy K, Vinayak V. Rao
article en

Abstract

Polymeric insulators are important components in a power system network. Failure of a single polymeric insulator poses serious threat to reliability of electrical utilities. Polymeric insulator due to its organic nature, degrades when various stresses act on it. This degradation eventually cause flashover, shortening its service life span. The degradation expedites when they work under contaminated conditions. Electric field distribution analysis is critical to access the failure of an insulator. If electric field reaches a critical value, it may result in flashover and eventually failure of the insulator. The present work concentrates on modeling of 220kV and 400kV polymeric insulators using ANSYS-LF software. Electric field evaluation was carried out on these insulators with and without corona disc. Results indicate that with insertion of the corona disc, there is a decrease in E-field values at the triplen junction which is below the threshold value. This is the prime factor which inhibits the occurrence of flashover, thereby improving its service lifespan under contaminated conditions. Further practical scenarios such as bird pecking, brittle fracture are studied. The studies highlight sharp increase in electric field values due to reduction in creepage distance. These studies will help the design engineer to select the suitable profile of the insulator to suit harsh environment.

M S Ramaiah University of Applied Sciences (IN)
Affordable and clean energy
Openalex Percentile: Top 82%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electric field estimation of 220kV and 400kV polymeric insulators using ANSYS-LF used in transmission lines — Pradipkumar Dixit, Ramakrishna Murthy K, et al. · (2024) | TGRS Research Map | TGRS