Study on corona loss characteristics of two types of 8 bundle conductors at an altitude of 4300m

Corona loss is an important factor in the construction of ultra-high voltage (UHV) alternating current (AC) transmission lines. There is little research on the corona loss associated with multiple bundle conductors for UHV AC projects situated at altitudes exceeding 4000 m. To address this gap, this paper conducted a study at the Yangbajing Experimental Base in Tibet at an altitude of 4300m. Utilizing a large UHV corona cage and an integrated photoelectric corona loss measurement system, the study investigated the corona loss characteristics of two types of 8-bundle test conductors under dry, heavy rain, and wet conditions. The investigation yielded corona loss values under varying field strengths and analyzed the impact of rainfall and field strength on conductor corona losses at extreme altitudes. Subsequently, by taking the 1000 kV UHV AC single circuit transmission project as an example, the equivalent method of corona loss was employed to evaluate the corona loss of transmission line conductors at an altitude of 4300 m. The research results can serve as a reference for the construction of UHV AC transmission lines in extremely high-altitude areas of China.

Authors

Institutions

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1109/iseae64934.2025.11041816
Primary Topic
Aerodynamics and Fluid Dynamics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on corona loss characteristics of two types of 8 bundle conductors at an altitude of 4300m

F. Zhang, Xingfa Liu, Jintian Liu, Xiaojuan Li et al.
2 links
Aerodynamics and Fluid Dynamics Research
article

Study on corona loss characteristics of two types of 8 bundle conductors at an altitude of 4300m

F. Zhang, Xingfa Liu, Jintian Liu, Xiaojuan Li, Baoquan Wan, Wangling He
article en

Abstract

Corona loss is an important factor in the construction of ultra-high voltage (UHV) alternating current (AC) transmission lines. There is little research on the corona loss associated with multiple bundle conductors for UHV AC projects situated at altitudes exceeding 4000 m. To address this gap, this paper conducted a study at the Yangbajing Experimental Base in Tibet at an altitude of 4300m. Utilizing a large UHV corona cage and an integrated photoelectric corona loss measurement system, the study investigated the corona loss characteristics of two types of 8-bundle test conductors under dry, heavy rain, and wet conditions. The investigation yielded corona loss values under varying field strengths and analyzed the impact of rainfall and field strength on conductor corona losses at extreme altitudes. Subsequently, by taking the 1000 kV UHV AC single circuit transmission project as an example, the equivalent method of corona loss was employed to evaluate the corona loss of transmission line conductors at an altitude of 4300 m. The research results can serve as a reference for the construction of UHV AC transmission lines in extremely high-altitude areas of China.

North China Electric Power University (CN), China Electric Power Research Institute
Openalex Percentile: Top 81%
Aerodynamics and Fluid Dynamics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on corona loss characteristics of two types of 8 bundle conductors at an altitude of 4300m — F. Zhang, Xingfa Liu, et al. · (2025) | TGRS Research Map | TGRS