Assessment of Abnormal Aging in AC Three-Phase Cables Based on Apparent Dielectric Loss Factor

As power cables remain in operation for extended periods, their insulation gradually ages, increasing the risk of insulation failure. This paper focuses on the detection and analysis of leakage currents in cable insulation within AC systems by means of a dual current transformer (CT) method. A calculation method based on phase angle normalization is proposed to determine the apparent dielectric loss angle (△δ) and apparent dielectric loss factor (tan△δ), enabling a more accurate assessment of cable aging. Through artificial cable aging tests, it is proven that the tan△δ exhibits more significant changes compared to the actual dielectric loss factor. The former can reach up to 144.73 times the reference value, while the latter is only 10.49 times, demonstrating the rationality and superiority of tan△δ in cable aging assessment. Measurements and analyses of apparent dielectric loss parameters were then conducted on three actual transmission lines with operational durations ranging from 1 to 12 years. The results show that the tan△δ of cables operated for one year is 0.14, while those in service for 10 to 12 years can reach 0.50‒1.40. These findings confirm that the proposed method effectively reflects the aging status of operating power cables. The conclusions of this study provide a new reference for assessing the aging of operating cables.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-06-24
DOI
https://doi.org/10.1109/tdei.2025.3582748
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Abnormal Aging in AC Three-Phase Cables Based on Apparent Dielectric Loss Factor

Xinhan Qiao, Yi Zhang, Tonghui Ye, Dongdong Zhang et al.
IEEE Transactions on Dielectrics and Electrical Insulation
High voltage insulation and dielectric phenomena
article

Assessment of Abnormal Aging in AC Three-Phase Cables Based on Apparent Dielectric Loss Factor

Xinhan Qiao, Yi Zhang, Tonghui Ye, Dongdong Zhang, Jicheng Yu, Gang Liu, Ao Han
article en

Abstract

As power cables remain in operation for extended periods, their insulation gradually ages, increasing the risk of insulation failure. This paper focuses on the detection and analysis of leakage currents in cable insulation within AC systems by means of a dual current transformer (CT) method. A calculation method based on phase angle normalization is proposed to determine the apparent dielectric loss angle (△δ) and apparent dielectric loss factor (tan△δ), enabling a more accurate assessment of cable aging. Through artificial cable aging tests, it is proven that the tan△δ exhibits more significant changes compared to the actual dielectric loss factor. The former can reach up to 144.73 times the reference value, while the latter is only 10.49 times, demonstrating the rationality and superiority of tan△δ in cable aging assessment. Measurements and analyses of apparent dielectric loss parameters were then conducted on three actual transmission lines with operational durations ranging from 1 to 12 years. The results show that the tan△δ of cables operated for one year is 0.14, while those in service for 10 to 12 years can reach 0.50‒1.40. These findings confirm that the proposed method effectively reflects the aging status of operating power cables. The conclusions of this study provide a new reference for assessing the aging of operating cables.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 33(1)
State Grid Corporation of China (China) (CN), China University of Mining and Technology (CN), Nanjing Institute of Technology (CN), China Electric Power Research Institute
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Natural Science Foundation of Hubei Province, Qinglan Project of Jiangsu Province of China
Openalex Percentile: Top 90%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.