Data-Driven Calibration for Wearable Brain Functional Imaging Devices

Recent advancements in near-infrared spectroscopy (NIRS) and associated optical techniques have significantly contributed to the development of wearable neuroimaging devices capable of capturing real-time neuronal activity with enhanced spatial and temporal resolution. However, despite these advancements, calibration remains a persistent challenge due to variability in NIRS sensor design, which can significantly degrade data quality. In this paper we introduce a universal data-driven calibration method designed to enhance the precision and reliability of NIRS sensor measurement. The proposed method integrates gradient descent–based optimisation with constraint-guided clustering to iteratively minimise calibration errors under realistic usage conditions. To evaluate its effectiveness, the algorithm was tested using an in-silico phantom constructed in MATLAB/NIRFAST, demonstrating notable improvements in signal clarity and haemoglobin concentration estimation. Additionally, the approach exhibits robustness to motion artefacts, thereby improving measurement fidelity. These contributions advance the reliability and accessibility of wearable brain imaging systems, enabling broader applications in both neuroscience research and clinical diagnostics.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.1109/cec65147.2025.11043082
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-Driven Calibration for Wearable Brain Functional Imaging Devices

Yunyi Zhao, Bo Pang, Shufan Yang
1 links
Optical Imaging and Spectroscopy Techniques
article

Data-Driven Calibration for Wearable Brain Functional Imaging Devices

Yunyi Zhao, Bo Pang, Shufan Yang
article en

Abstract

Recent advancements in near-infrared spectroscopy (NIRS) and associated optical techniques have significantly contributed to the development of wearable neuroimaging devices capable of capturing real-time neuronal activity with enhanced spatial and temporal resolution. However, despite these advancements, calibration remains a persistent challenge due to variability in NIRS sensor design, which can significantly degrade data quality. In this paper we introduce a universal data-driven calibration method designed to enhance the precision and reliability of NIRS sensor measurement. The proposed method integrates gradient descent–based optimisation with constraint-guided clustering to iteratively minimise calibration errors under realistic usage conditions. To evaluate its effectiveness, the algorithm was tested using an in-silico phantom constructed in MATLAB/NIRFAST, demonstrating notable improvements in signal clarity and haemoglobin concentration estimation. Additionally, the approach exhibits robustness to motion artefacts, thereby improving measurement fidelity. These contributions advance the reliability and accessibility of wearable brain imaging systems, enabling broader applications in both neuroscience research and clinical diagnostics.

University of Leeds (GB), University College London (GB)
Affordable and clean energy
Openalex Percentile: Top 78%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Data-Driven Calibration for Wearable Brain Functional Imaging Devices — Yunyi Zhao, Bo Pang, et al. · (2025) | TGRS Research Map | TGRS