Comparing Occupational Exposure from <sup>18</sup>F-FDG Injection Procedure Using a Traditional Injection Method Versus an Automated Injection System

We evaluated occupational radiation exposure associated with <sup>18</sup>F-FDG injection using a traditional manual approach versus an automated injection system. <b>Methods:</b> Wrist and whole-body radiation exposure of nuclear medicine personnel using a manual injection method versus an automated injection system for <sup>18</sup>F-FDG administration were assessed using electronic personal dosimeters. Radiation exposure while configuring both systems was also evaluated. The dose administered met the requirements of the "as low as reasonably achievable" principle. Radiation exposure during initial setup and dose administration, residual activity, dose accuracy, presence of contamination, and frequency of extravasation were compared between methods. <b>Results:</b> Compared with the traditional manual method, use of the automated injection system resulted in significantly lower mean radiation exposure to medical physicists' wrists (<i>P</i> < 0.01). Radiation exposure was 79.41% lower at the wrist while using the automated injection system. Differences in whole-body radiation exposure were not significant between injection methods (<i>P</i> < 0.56). The overall radiation dose per injection at the wrist and in the whole body and mean residual activity after injection were noticeably lower with the automated system (<i>P</i> < 0.01), with mean residual activity decreasing by 73.58%. <b>Conclusion:</b> The overall radiation exposure for nuclear medicine personnel was significantly decreased when administering <sup>18</sup>F-FDG via an automated injection system.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine Technology
Published
2025-06-24
DOI
https://doi.org/10.2967/jnmt.124.269103
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing Occupational Exposure from 18F-FDG Injection Procedure Using a Traditional Injection Method Versus an Automated Injection System

Raju Kumar Gupta, Shantanu Pande, Ashwin Shinde
1 citations
Journal of Nuclear Medicine Technology
Radiation Dose and Imaging
1.36
article

Comparing Occupational Exposure from 18F-FDG Injection Procedure Using a Traditional Injection Method Versus an Automated Injection System

Raju Kumar Gupta, Shantanu Pande, Ashwin Shinde
article en
1 citations

Abstract

We evaluated occupational radiation exposure associated with <sup>18</sup>F-FDG injection using a traditional manual approach versus an automated injection system. <b>Methods:</b> Wrist and whole-body radiation exposure of nuclear medicine personnel using a manual injection method versus an automated injection system for <sup>18</sup>F-FDG administration were assessed using electronic personal dosimeters. Radiation exposure while configuring both systems was also evaluated. The dose administered met the requirements of the "as low as reasonably achievable" principle. Radiation exposure during initial setup and dose administration, residual activity, dose accuracy, presence of contamination, and frequency of extravasation were compared between methods. <b>Results:</b> Compared with the traditional manual method, use of the automated injection system resulted in significantly lower mean radiation exposure to medical physicists' wrists (<i>P</i> < 0.01). Radiation exposure was 79.41% lower at the wrist while using the automated injection system. Differences in whole-body radiation exposure were not significant between injection methods (<i>P</i> < 0.56). The overall radiation dose per injection at the wrist and in the whole body and mean residual activity after injection were noticeably lower with the automated system (<i>P</i> < 0.01), with mean residual activity decreasing by 73.58%. <b>Conclusion:</b> The overall radiation exposure for nuclear medicine personnel was significantly decreased when administering <sup>18</sup>F-FDG via an automated injection system.

Journal of Nuclear Medicine TechnologyVol. 53(3)
All India Institute of Medical Sciences, Nagpur (IN)
Openalex Percentile: Top 19%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.