Performance of 9 to 15 MV Computed Tomography of large objects in industrial and nuclear field

As part of its R&D programs on large objects characterization, the Nuclear Measurement Laboratory at the CEA-Cadarache center has equipped its high-energy tomograph with a new linear accelerator (linac): a VAREX K15 (9 to 15 MV range). This linac delivers a very high dose rate: up to 130 Gy/min at 1 m from the target. Combined with a mechanical bench and optimized detectors, this X-ray source allows handling very large objects for radiographies and tomographies, up to 1600 mm in diameter and 5 t in mass [1]. Compared with the kilovoltage range, MV energies offer two advantages: higher photon flux and deeper penetration capabilities (steel from 100 to 400 mm). The new X-ray source has been fully characterized in terms of dose rate, focal spot size and photon spectrum using water attenuation measurements. Depending on the geometry of the object to be scanned, two detectors can be used. The first is dedicated to larger objects and is a lens-based detector with different scintillator screens (Gadox or CsI, as described in [2]) specially designed for this configuration (with a screen size up to 800x600 mm2). The second, a commercial flat-panel with a small pixel pitch (0.1 mm) is used for the smallest but densest objects, where the spatial resolution is critical [3]. The performance of these detectors is characterized, compared and discussed. The tomograph set-up and its final performance at low (9 MV) and high (15 MV) energies are detailed in terms of MTF curves, and contrast-over-noise ratio obtained on specific mock-ups. Examples of tomography on real objects (industrial packages produced by metal additive manufacturing or radioactive waste drums) are also presented. Finally, the main drawbacks in this energy range are listed and detailed: 1) the scattering background caused by the Compton effect, 2) the thickness of the scintillator, which must be optimized according to the spatial resolution or expected efficiency and 3) the size of the X-ray source (limited to 1.5 mm). To overcome these limitations, various studies are currently underway, and the expected solutions are presented and discussed.

Authors

Publication Details

Journal
e-Journal of Nondestructive Testing
Published
2025-06-24
DOI
https://doi.org/10.58286/31408
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of 9 to 15 MV Computed Tomography of large objects in industrial and nuclear field

B. Geslot, Olivier David, Alix Sardet, Christophe Roure et al.
e-Journal of Nondestructive Testing
Advanced X-ray and CT Imaging
article

Performance of 9 to 15 MV Computed Tomography of large objects in industrial and nuclear field

B. Geslot, Olivier David, Alix Sardet, Christophe Roure, Daniel J. Eck, Nicolas Estre, E. Payan, Frédéric Moutet, Cécilia Tarpaut, Olivier Guetion
article en

Abstract

As part of its R&D programs on large objects characterization, the Nuclear Measurement Laboratory at the CEA-Cadarache center has equipped its high-energy tomograph with a new linear accelerator (linac): a VAREX K15 (9 to 15 MV range). This linac delivers a very high dose rate: up to 130 Gy/min at 1 m from the target. Combined with a mechanical bench and optimized detectors, this X-ray source allows handling very large objects for radiographies and tomographies, up to 1600 mm in diameter and 5 t in mass [1]. Compared with the kilovoltage range, MV energies offer two advantages: higher photon flux and deeper penetration capabilities (steel from 100 to 400 mm). The new X-ray source has been fully characterized in terms of dose rate, focal spot size and photon spectrum using water attenuation measurements. Depending on the geometry of the object to be scanned, two detectors can be used. The first is dedicated to larger objects and is a lens-based detector with different scintillator screens (Gadox or CsI, as described in [2]) specially designed for this configuration (with a screen size up to 800x600 mm2). The second, a commercial flat-panel with a small pixel pitch (0.1 mm) is used for the smallest but densest objects, where the spatial resolution is critical [3]. The performance of these detectors is characterized, compared and discussed. The tomograph set-up and its final performance at low (9 MV) and high (15 MV) energies are detailed in terms of MTF curves, and contrast-over-noise ratio obtained on specific mock-ups. Examples of tomography on real objects (industrial packages produced by metal additive manufacturing or radioactive waste drums) are also presented. Finally, the main drawbacks in this energy range are listed and detailed: 1) the scattering background caused by the Compton effect, 2) the thickness of the scintillator, which must be optimized according to the spatial resolution or expected efficiency and 3) the size of the X-ray source (limited to 1.5 mm). To overcome these limitations, various studies are currently underway, and the expected solutions are presented and discussed.

e-Journal of Nondestructive TestingVol. 30(8)
Openalex Percentile: Top 86%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.