Effect of poly-L-lysine for graphene FET biosensor in acetate buffer for highly sensitive detection of SARS-CoV-2

Abstract To increase the sensitivity of the graphene Field effect transistor (GFET) for viral detection, an acetate buffer at pH 4 was used instead of the conventional phosphate-buffer saline (PBS) at pH 7. We hypothesize that SARS-CoV-2 carries more positive charges in the acetate buffer, as its pH is further from the isoelectric point of SARS-CoV-2 (pI 5.2–6.0) compared to that of PBS. Additionally, GFET measurement results with and without poly-L-lysine (PLL) modification were compared. The dependence of sensitivity on the surface charge of graphene was estimated by solving the Poisson–Boltzmann equation, and the effect of PLL modification on this dependence was discussed.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Applied Physics
Published
2025-06-24
DOI
https://doi.org/10.35848/1347-4065/ade7de
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of poly-L-lysine for graphene FET biosensor in acetate buffer for highly sensitive detection of SARS-CoV-2

Masahiko Kimura, Shinsuke Tani, Hidekazu Tanaka, Kaori Yamamoto et al.
Japanese Journal of Applied Physics
Advanced biosensing and bioanalysis techniques
article

Effect of poly-L-lysine for graphene FET biosensor in acetate buffer for highly sensitive detection of SARS-CoV-2

Masahiko Kimura, Shinsuke Tani, Hidekazu Tanaka, Kaori Yamamoto, Shota Ushiba, Kiyoji Sakano, Kazuhiko Matsumoto, Kouichi Inoue, Y. Watanabe, Eriko Ohnishi, Mamiko Yano, Natsuki Sato
article en

Abstract

Abstract To increase the sensitivity of the graphene Field effect transistor (GFET) for viral detection, an acetate buffer at pH 4 was used instead of the conventional phosphate-buffer saline (PBS) at pH 7. We hypothesize that SARS-CoV-2 carries more positive charges in the acetate buffer, as its pH is further from the isoelectric point of SARS-CoV-2 (pI 5.2–6.0) compared to that of PBS. Additionally, GFET measurement results with and without poly-L-lysine (PLL) modification were compared. The dependence of sensitivity on the surface charge of graphene was estimated by solving the Poisson–Boltzmann equation, and the effect of PLL modification on this dependence was discussed.

Japanese Journal of Applied PhysicsVol. 64(7)
Jikei University School of Medicine (JP), Murata (Japan) (JP), The University of Osaka (JP)
JST-Mirai Program
Openalex Percentile: Top 87%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of poly-L-lysine for graphene FET biosensor in acetate buffer for highly sensitive detection of SARS-CoV-2 — Masahiko Kimura, Shinsuke Tani, et al. · Japanese Journal of Applied Physics (2025) | TGRS Research Map | TGRS