Association of serum metallic ion levels in patients with total joint arthroplasty with their adverse effects: a comparative cross-sectional study

Background: Metallic implants used in joint arthroplasty release ions gradually sometimes resulting in their toxicity. Hence, data regarding exact correlation between serum metallic ion levels and toxicity occurrence is still lacking. Methods: A total of 90 adult subjects, each with a single total joint arthroplasty (TJA between 1 to 5 years), or without were recruited. The serum levels of Cr, Co, Ni, & Mo in above 2 groups were estimated and correlated with signs and symptoms related to Cr, Co, Ni, & Mo ion toxicity Unpaired Student's t-test, Chi-square test and Pearson correlation coefficient were used to analyses data. A p value<0.05 was considered significant. Results: The mean serum levels of Cr (21.53±7448 µg/l vs. 19.03±0.3372 µg/l; p=0.0026), Ni (9.643±0.2486 µg/l vs. 9.303±0.2729 µg/l; p=0.83), Co (5.482±0.20 µg/l vs. 5.573±0.21 µg/l; p=0.76), and Mo (5.573±0.2159 µg/l vs. 5.290±0.2208 µg/l; p=0.36) in subjects with implants were higher than in subjects without implants. Five subjects reported six adverse effects (AE) specifically numbness in hands (4), fatigue (1), and bone pain (1), which showed no significant association or correlation with the mean serum levels of the metallic ions. Conclusion: Results showed increased mean serum chromium levels post one year of implant surgery, while mean serum levels of Co, Ni, and Mo did not demonstrate any significant elevation. No correlation between serum levels of Cr, Co, Ni, and Mo, duration of implant, and observed AE was seen. Causality assessment between reported AE and metal ions (Cr, Co, Ni, and Mo) levels was “possible."

Authors

Institutions

Publication Details

Journal
International Journal of Research in Orthopaedics
Published
2025-06-24
DOI
https://doi.org/10.18203/issn.2455-4510.intjresorthop20251796
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association of serum metallic ion levels in patients with total joint arthroplasty with their adverse effects: a comparative cross-sectional study

J. B. Singh, Rakhi Singh, Harmeet Singh Rehan, Mukesh Kalra et al.
International Journal of Research in Orthopaedics
Orthopaedic implants and arthroplasty
article

Association of serum metallic ion levels in patients with total joint arthroplasty with their adverse effects: a comparative cross-sectional study

J. B. Singh, Rakhi Singh, Harmeet Singh Rehan, Mukesh Kalra, Lalit Gupta, Tarun Arora, Mukul Das
article en

Abstract

Background: Metallic implants used in joint arthroplasty release ions gradually sometimes resulting in their toxicity. Hence, data regarding exact correlation between serum metallic ion levels and toxicity occurrence is still lacking. Methods: A total of 90 adult subjects, each with a single total joint arthroplasty (TJA between 1 to 5 years), or without were recruited. The serum levels of Cr, Co, Ni, & Mo in above 2 groups were estimated and correlated with signs and symptoms related to Cr, Co, Ni, & Mo ion toxicity Unpaired Student's t-test, Chi-square test and Pearson correlation coefficient were used to analyses data. A p value<0.05 was considered significant. Results: The mean serum levels of Cr (21.53±7448 µg/l vs. 19.03±0.3372 µg/l; p=0.0026), Ni (9.643±0.2486 µg/l vs. 9.303±0.2729 µg/l; p=0.83), Co (5.482±0.20 µg/l vs. 5.573±0.21 µg/l; p=0.76), and Mo (5.573±0.2159 µg/l vs. 5.290±0.2208 µg/l; p=0.36) in subjects with implants were higher than in subjects without implants. Five subjects reported six adverse effects (AE) specifically numbness in hands (4), fatigue (1), and bone pain (1), which showed no significant association or correlation with the mean serum levels of the metallic ions. Conclusion: Results showed increased mean serum chromium levels post one year of implant surgery, while mean serum levels of Co, Ni, and Mo did not demonstrate any significant elevation. No correlation between serum levels of Cr, Co, Ni, and Mo, duration of implant, and observed AE was seen. Causality assessment between reported AE and metal ions (Cr, Co, Ni, and Mo) levels was “possible."

International Journal of Research in OrthopaedicsVol. 11(4)
Global Hospitals (IN), Shriram Institute for Industrial Research (IN), Lipomic Healthcare (India) (IN)
Openalex Percentile: Top 75%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.