Arrhythmia Inducibility in the CAVB Dog Model, A Critical Analysis on Underlying Factors

The dog with chronic atrioventricular block (CAVB) combines a number of risk factors associated with Torsade de Pointes (TdP) arrhythmias. Nevertheless, approximately 33% of the animals are resistant to dofetilide-induced TdP arrhythmia. Of a group of 78 experimentally identical CAVB dogs, we compared TdP inducible vs. non-inducible animals for a set of basic, and cardiac electrical and mechanical parameters. Body weight, but not sex or age, is associated with TdP inducibility. Of the cardiac parameters, longer ventricular repolarization duration and increased contractility at baseline are associated with dofetilide-induced TdP arrhythmias. Differences in cardiac parameters disappeared upon dofetilide infusion. We discuss that prolonged repolarization and increased contractility may be early indications of calcium-mediated early after depolarization that may develop into TdP arrhythmias.

Authors

Institutions

Publication Details

Journal
Cardiovascular Toxicology
Published
2025-06-24
DOI
https://doi.org/10.1007/s12012-025-10033-3
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Arrhythmia Inducibility in the CAVB Dog Model, A Critical Analysis on Underlying Factors

Marcel A. G. van der Heyden, Marc A. Vos, Joanne J.A. van Bavel, Henriëtte D.M. Beekman et al.
Cardiovascular Toxicology
Cardiac electrophysiology and arrhythmias
article

Arrhythmia Inducibility in the CAVB Dog Model, A Critical Analysis on Underlying Factors

Marcel A. G. van der Heyden, Marc A. Vos, Joanne J.A. van Bavel, Henriëtte D.M. Beekman, Marien J. C. Houtman
article en

Abstract

The dog with chronic atrioventricular block (CAVB) combines a number of risk factors associated with Torsade de Pointes (TdP) arrhythmias. Nevertheless, approximately 33% of the animals are resistant to dofetilide-induced TdP arrhythmia. Of a group of 78 experimentally identical CAVB dogs, we compared TdP inducible vs. non-inducible animals for a set of basic, and cardiac electrical and mechanical parameters. Body weight, but not sex or age, is associated with TdP inducibility. Of the cardiac parameters, longer ventricular repolarization duration and increased contractility at baseline are associated with dofetilide-induced TdP arrhythmias. Differences in cardiac parameters disappeared upon dofetilide infusion. We discuss that prolonged repolarization and increased contractility may be early indications of calcium-mediated early after depolarization that may develop into TdP arrhythmias.

Cardiovascular ToxicologyVol. 25(9)
University Medical Center Utrecht (NL)
Good health and well-being
Openalex Percentile: Top 75%
Cardiac electrophysiology and arrhythmias
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Arrhythmia Inducibility in the CAVB Dog Model, A Critical Analysis on Underlying Factors — Marcel A. G. van der Heyden, Marc A. Vos, et al. · Cardiovascular Toxicology (2025) | TGRS Research Map | TGRS