Vibration reduction of electric equipment using an electromagnetic dynamic vibration absorber: Shaking table tests and numerical simulations

This study proposes an electromagnetic dynamic vibration absorber (EMDVA) to reduce the seismic vibration of equipment in nuclear power plants . Its effectiveness is validated through shaking table tests of the integrated equipment-EMDVA system, with excitations generated by a thorium molten salt reactor (TMSR) model, considering the interaction with soil and plant structures. The EMDVA, integrating linear springs and electromagnetic spring elements with nonlinear stiffness, achieving a wide control frequency range while reducing sensitivity to variations in excitation amplitude. The damping mechanism is analyzed through theoretical and experimental studies of electromagnetic springs. Results reveal that the EMDVA transfers vibration energy to a wider frequency range and dissipates it quickly, outperforming the linear DVA in electrical cabinets. Increasing nonlinear stiffness broadens the control bandwidth but reduces stability to excitation amplitude variations. Parameter analysis shows that when the initial nonlinear stiffness proportion is 50–80 %, the EMDVA offers a significantly wider control bandwidth with minimal sensitivity increase. Under intense excitations, the EMDVA can decrease the maximum working stroke compared to the DVA, making it more suitable for space-constrained equipment applications. • An electromagnetic dynamic vibration absorber is proposed for electric equipment. • Simulation method for equipment installed with EMDVA is validated by experiment. • EMDVA offers superior vibration control over linear DVA across broader frequencies. • Shaking table tests validate EMDVA’s effectiveness in nuclear electric equipment.

Authors

Publication Details

Journal
Engineering Structures
Published
2025-06-24
DOI
https://doi.org/10.1016/j.engstruct.2025.120808
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vibration reduction of electric equipment using an electromagnetic dynamic vibration absorber: Shaking table tests and numerical simulations

Zheng Lu, Zhao-Dong Xu, Shuai Gao, Hongjing Xue et al.
Engineering Structures
Vibration Control and Rheological Fluids
article

Vibration reduction of electric equipment using an electromagnetic dynamic vibration absorber: Shaking table tests and numerical simulations

Zheng Lu, Zhao-Dong Xu, Shuai Gao, Hongjing Xue, Guowei Zhang, Mengyao Zhou
article en

Abstract

This study proposes an electromagnetic dynamic vibration absorber (EMDVA) to reduce the seismic vibration of equipment in nuclear power plants . Its effectiveness is validated through shaking table tests of the integrated equipment-EMDVA system, with excitations generated by a thorium molten salt reactor (TMSR) model, considering the interaction with soil and plant structures. The EMDVA, integrating linear springs and electromagnetic spring elements with nonlinear stiffness, achieving a wide control frequency range while reducing sensitivity to variations in excitation amplitude. The damping mechanism is analyzed through theoretical and experimental studies of electromagnetic springs. Results reveal that the EMDVA transfers vibration energy to a wider frequency range and dissipates it quickly, outperforming the linear DVA in electrical cabinets. Increasing nonlinear stiffness broadens the control bandwidth but reduces stability to excitation amplitude variations. Parameter analysis shows that when the initial nonlinear stiffness proportion is 50–80 %, the EMDVA offers a significantly wider control bandwidth with minimal sensitivity increase. Under intense excitations, the EMDVA can decrease the maximum working stroke compared to the DVA, making it more suitable for space-constrained equipment applications. • An electromagnetic dynamic vibration absorber is proposed for electric equipment. • Simulation method for equipment installed with EMDVA is validated by experiment. • EMDVA offers superior vibration control over linear DVA across broader frequencies. • Shaking table tests validate EMDVA’s effectiveness in nuclear electric equipment.

Engineering StructuresVol. 341
National Natural Science Foundation of China, Beijing University of Civil Engineering and Architecture
Affordable and clean energy
Openalex Percentile: Top 85%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Vibration reduction of electric equipment using an electromagnetic dynamic vibration absorber: Shaking table tests and numerical simulations — Zheng Lu, Zhao-Dong Xu, et al. · Engineering Structures (2025) | TGRS Research Map | TGRS