Fault diagnosis method for low-voltage circuit breakers based on BWO-SCN

Low-voltage air circuit breaker is an important part of power system, its hard to detect internal faults under long-term operation condition. Therefore, fault diagnosis of low-voltage circuit breakers has always been a research hotspot. This article takes RGW1 low-voltage universal air circuit breaker as the research object, A fault diagnosis method of low-voltage air circuit breaker based on Multi-Resolution Singular Value Decomposition (MRSVD) denoising and Beluga Whale Optimization (BWO) optimize Stochastic Configuration Networks (SCN) is proposed. Firstly, the closing vibration signals under different fault states are collected and MRSVD is used for noise reduction. Secondly, Variational Mode Decomposition (VMD) was used to decompose the denoised signal, and the sample entropy of each component was extracted as the feature vector. Finally, the BWO was used to optimize the SCN(BWO-SCN), The feature vector was used as the input of the model, and the fault category was used as the output. Accuracy, Confusion Matrix and Receiver Operating Characteristic (ROC) curve were used as evaluation indexes. The results show that the proposed method can identify the vibration signals under different fault states of circuit breakers with high accuracy.

Authors

Institutions

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1109/iseae64934.2025.11041917
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault diagnosis method for low-voltage circuit breakers based on BWO-SCN

Shi‐Wei Qu
Smart Grid and Power Systems
article

Fault diagnosis method for low-voltage circuit breakers based on BWO-SCN

Shi‐Wei Qu
article en

Abstract

Low-voltage air circuit breaker is an important part of power system, its hard to detect internal faults under long-term operation condition. Therefore, fault diagnosis of low-voltage circuit breakers has always been a research hotspot. This article takes RGW1 low-voltage universal air circuit breaker as the research object, A fault diagnosis method of low-voltage air circuit breaker based on Multi-Resolution Singular Value Decomposition (MRSVD) denoising and Beluga Whale Optimization (BWO) optimize Stochastic Configuration Networks (SCN) is proposed. Firstly, the closing vibration signals under different fault states are collected and MRSVD is used for noise reduction. Secondly, Variational Mode Decomposition (VMD) was used to decompose the denoised signal, and the sample entropy of each component was extracted as the feature vector. Finally, the BWO was used to optimize the SCN(BWO-SCN), The feature vector was used as the input of the model, and the fault category was used as the output. Accuracy, Confusion Matrix and Receiver Operating Characteristic (ROC) curve were used as evaluation indexes. The results show that the proposed method can identify the vibration signals under different fault states of circuit breakers with high accuracy.

Liaoning Technical University (CN)
Openalex Percentile: Top 87%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault diagnosis method for low-voltage circuit breakers based on BWO-SCN — Shi‐Wei Qu · (2025) | TGRS Research Map | TGRS