Analysis and Treatment of Vibration Differences in Air Cooler Fans at Gas Transmission Stations

This paper focuses on the vibration differences of air cooler fans in gas transmission stations. Vibration anomalies occur in the operation of air cooler fans supporting compressors in a station for west-east gas transmission, and the vibration of KL_3 fan of No.1 air cooler is particularly prominent, and the overall vibration displacement and velocity values of No.2 air cooler fan show complex changes at different times and are higher than those of No.1 air cooler fan. By installing vibration measurement points in the fan drive motor and collecting data through relevant software and conducting spectrum analysis, it was found that the abnormal vibration of fan KL_3 was caused by rotor imbalance and eccentricity; the large vibration of fan of air cooler No. 2 was caused by factors such as poor rigidity of the equipment connection and installation and foundation, the poor condition of its own structural components and differences in operating conditions. In view of these problems, after taking measures such as tightening bolts, reinforcing foundation, impeller weighting, and replacing bearings, the vibration of KL_3 fan and No.2 air-cooler fan have been effectively improved, which provides an important reference for the operation and maintenance of similar equipment.

Authors

Institutions

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1109/iseae64934.2025.11041803
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Treatment of Vibration Differences in Air Cooler Fans at Gas Transmission Stations

Lei Wang, Lingzhi Ge, Zhengrong Yang
Advanced Sensor and Control Systems
article

Analysis and Treatment of Vibration Differences in Air Cooler Fans at Gas Transmission Stations

Lei Wang, Lingzhi Ge, Zhengrong Yang
article en

Abstract

This paper focuses on the vibration differences of air cooler fans in gas transmission stations. Vibration anomalies occur in the operation of air cooler fans supporting compressors in a station for west-east gas transmission, and the vibration of KL_3 fan of No.1 air cooler is particularly prominent, and the overall vibration displacement and velocity values of No.2 air cooler fan show complex changes at different times and are higher than those of No.1 air cooler fan. By installing vibration measurement points in the fan drive motor and collecting data through relevant software and conducting spectrum analysis, it was found that the abnormal vibration of fan KL_3 was caused by rotor imbalance and eccentricity; the large vibration of fan of air cooler No. 2 was caused by factors such as poor rigidity of the equipment connection and installation and foundation, the poor condition of its own structural components and differences in operating conditions. In view of these problems, after taking measures such as tightening bolts, reinforcing foundation, impeller weighting, and replacing bearings, the vibration of KL_3 fan and No.2 air-cooler fan have been effectively improved, which provides an important reference for the operation and maintenance of similar equipment.

Shanghai Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.