Topogram and 3DCT geometry calibration for image-guided proton therapy with in-room CT-on-rails

In-room computer tomography (CT) on-rails scanners are available in proton therapy centers but often limited to control imaging, due to geometric distortion and lack of integration. We present a calibration method combining CT-on-rails with a robotic table to achieve sub-millimeter patient positioning accuracy. Geometric distortions in 3DCT and topogram images were corrected using affine models and validated with laser tracker data. Phantom experiments simulating clinical conditions showed errors below 0.15 mm for 3D/3D and 0.3-0.55 mm for 2D/3D registration, the latter using a novel algorithm for digitally reconstructed topograms. The workflow enables accurate positioning without isocenter verification, supporting high-precision radiotherapy.

Authors

Institutions

Publication Details

Journal
Physics and Imaging in Radiation Oncology
Published
2025-06-24
DOI
https://doi.org/10.1016/j.phro.2025.100799
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Topogram and 3DCT geometry calibration for image-guided proton therapy with in-room CT-on-rails

Sairos Safai, Giovanni Fattori, Riccardo Via, Antony Lomax
Physics and Imaging in Radiation Oncology
Radiation Therapy and Dosimetry
article

Topogram and 3DCT geometry calibration for image-guided proton therapy with in-room CT-on-rails

Sairos Safai, Giovanni Fattori, Riccardo Via, Antony Lomax
article en

Abstract

In-room computer tomography (CT) on-rails scanners are available in proton therapy centers but often limited to control imaging, due to geometric distortion and lack of integration. We present a calibration method combining CT-on-rails with a robotic table to achieve sub-millimeter patient positioning accuracy. Geometric distortions in 3DCT and topogram images were corrected using affine models and validated with laser tracker data. Phantom experiments simulating clinical conditions showed errors below 0.15 mm for 3D/3D and 0.3-0.55 mm for 2D/3D registration, the latter using a novel algorithm for digitally reconstructed topograms. The workflow enables accurate positioning without isocenter verification, supporting high-precision radiotherapy.

Physics and Imaging in Radiation OncologyVol. 35
Paul Scherrer Institute (CH), ETH Zurich (CH)
Eidgenössische Technische Hochschule Zürich
Openalex Percentile: Top 76%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Topogram and 3DCT geometry calibration for image-guided proton therapy with in-room CT-on-rails — Sairos Safai, Giovanni Fattori, et al. · Physics and Imaging in Radiation Oncology (2025) | TGRS Research Map | TGRS