Experimental and numerical study of strain distributions and shear lag effects in FRP tendon pull-out experiments

In the present study, sand-coated carbon fiber reinforced polymer (CFRP) tendons were instrumented with integrated optical fibers. The direct integration during manufacturing did not affect the bond between tendon and concrete and resulted in an excellent measurement quality. The tendons were cast into concrete cubes with different embedment lengths of 5, 10 and 15 times the diameter. The bond between tendon and concrete was tested using direct pull-out tests. Not only the force and the end-slip were measured but also the strain distribution in the tendon. This allowed to derive a position-dependent local bond–slip curve. Significant deviations from the commonly measured average bond-stress vs. end-slip relationship were observed for long and short embedment lengths. A complementary finite element study confirmed that average bond-stress vs. end-slip curves cannot properly predict the strain distribution in pull-out experiments, especially for longer embedment lengths. This allows to conclude that strain distributions are highly affected by local effects, e.g. partial pull-out failure of the concrete. In addition, shear lag was identified as additional parameter affecting the measurements of optical fibers when integrated in materials with low shear stiffness. The shear lag is highly dependent on the radial and axial position and further affected by the tendon material, the diameter of the tendon and the magnitude of the shear stress. • Direct pull-out tests of sand-coated CFRP tendons and measurement of strain distributions. • High resolution strain measurements allow the determination of local bond stress-slip laws. • Comparison of average bond-stress vs. end-slip curves with local bond stress-slip curves. • Limitations of average bond-stress vs. end-slip laws for numerical modelling. • Modeling and estimation of shear lag effects in unidirectional FRP tendons.

Authors

Institutions

Publication Details

Journal
Cement and Concrete Composites
Published
2025-06-24
DOI
https://doi.org/10.1016/j.cemconcomp.2025.106189
Citations
1
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and numerical study of strain distributions and shear lag effects in FRP tendon pull-out experiments

Valentin Ott, Giovanni P. Terrasi, Mateusz Wyrzykowski, Pietro Lura et al.
1 citations
Cement and Concrete Composites
Structural Response to Dynamic Loads
0.95
article

Experimental and numerical study of strain distributions and shear lag effects in FRP tendon pull-out experiments

Valentin Ott, Giovanni P. Terrasi, Mateusz Wyrzykowski, Pietro Lura, Christian Affolter
article en
1 citations

Abstract

In the present study, sand-coated carbon fiber reinforced polymer (CFRP) tendons were instrumented with integrated optical fibers. The direct integration during manufacturing did not affect the bond between tendon and concrete and resulted in an excellent measurement quality. The tendons were cast into concrete cubes with different embedment lengths of 5, 10 and 15 times the diameter. The bond between tendon and concrete was tested using direct pull-out tests. Not only the force and the end-slip were measured but also the strain distribution in the tendon. This allowed to derive a position-dependent local bond–slip curve. Significant deviations from the commonly measured average bond-stress vs. end-slip relationship were observed for long and short embedment lengths. A complementary finite element study confirmed that average bond-stress vs. end-slip curves cannot properly predict the strain distribution in pull-out experiments, especially for longer embedment lengths. This allows to conclude that strain distributions are highly affected by local effects, e.g. partial pull-out failure of the concrete. In addition, shear lag was identified as additional parameter affecting the measurements of optical fibers when integrated in materials with low shear stiffness. The shear lag is highly dependent on the radial and axial position and further affected by the tendon material, the diameter of the tendon and the magnitude of the shear stress. • Direct pull-out tests of sand-coated CFRP tendons and measurement of strain distributions. • High resolution strain measurements allow the determination of local bond stress-slip laws. • Comparison of average bond-stress vs. end-slip curves with local bond stress-slip curves. • Limitations of average bond-stress vs. end-slip laws for numerical modelling. • Modeling and estimation of shear lag effects in unidirectional FRP tendons.

Cement and Concrete CompositesVol. 163
ETH Zurich (CH), Swiss Federal Laboratories for Materials Science and Technology (CH), University of Edinburgh (GB)
Openalex Percentile: Top 24%
Structural Response to Dynamic Loads
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.