Effect of Cation Contamination of Gas Diffusion Layer on Water Management and Performance of PEMFCs

ABSTRACT The efficient and stable operation of proton exchange membrane fuel cells (PEMFCs) in practical applications can be adversely affected by various contaminants. This study delves into the impact of Cr 2 (SO 4 ) 3 contamination on the gas diffusion layer (GDL) and PEMFC performance, systematically analyzing the physicochemical property changes and their correlation with electrochemical performance. The results indicate that after post‐treatment, the GDL surface exhibited exposed carbon fibers, cracks, and large pores in the microporous layer (MPL), with a noticeable detachment of PTFE. There was a marked reduction in C and F element signals, an increase in O element signals, deposition of Cr 2 (SO 4 ) 3 , formation of C=O and C=C bonds, appearance of Cr 2 (SO 4 ) 3 characteristic peaks, and changes in pore structure—all suggesting significant alterations in the GDL's surface morphology, structure, and chemical composition. The decline in mechanical strength and thermal stability, and increased surface roughness and resistance negatively impacted fuel cell performance. At high current densities, the emergence of water flooding increased mass transfer resistance from 0.1 Ω cm 2 to 1.968 Ω cm 2 , with a maximum power density decay rate reaching 71.17%. This study reveals the significant negative impact of Cr 2 (SO 4 ) 3 contamination on GDL and fuel cell performance, highlighting that changes in surface structure, reduced hydrophobicity, and increased mass transfer resistance are primary causes of performance degradation. The findings provide crucial insights for improving GDL materials, optimizing fuel cell manufacturing and operation processes, and addressing contamination issues in practical applications.

Authors

Institutions

Publication Details

Journal
Carbon Energy
Published
2025-06-24
DOI
https://doi.org/10.1002/cey2.70038
Citations
3
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Cation Contamination of Gas Diffusion Layer on Water Management and Performance of PEMFCs

Haijiang Wang, Jiashun Zhang, Hanwen Zhang, Ming Chen et al.
3 citations
Carbon Energy
Fuel Cells and Related Materials
2.19
article

Effect of Cation Contamination of Gas Diffusion Layer on Water Management and Performance of PEMFCs

Haijiang Wang, Jiashun Zhang, Hanwen Zhang, Ming Chen, Zhengnan Li, Huibing Chen
article en
3 citations

Abstract

ABSTRACT The efficient and stable operation of proton exchange membrane fuel cells (PEMFCs) in practical applications can be adversely affected by various contaminants. This study delves into the impact of Cr 2 (SO 4 ) 3 contamination on the gas diffusion layer (GDL) and PEMFC performance, systematically analyzing the physicochemical property changes and their correlation with electrochemical performance. The results indicate that after post‐treatment, the GDL surface exhibited exposed carbon fibers, cracks, and large pores in the microporous layer (MPL), with a noticeable detachment of PTFE. There was a marked reduction in C and F element signals, an increase in O element signals, deposition of Cr 2 (SO 4 ) 3 , formation of C=O and C=C bonds, appearance of Cr 2 (SO 4 ) 3 characteristic peaks, and changes in pore structure—all suggesting significant alterations in the GDL's surface morphology, structure, and chemical composition. The decline in mechanical strength and thermal stability, and increased surface roughness and resistance negatively impacted fuel cell performance. At high current densities, the emergence of water flooding increased mass transfer resistance from 0.1 Ω cm 2 to 1.968 Ω cm 2 , with a maximum power density decay rate reaching 71.17%. This study reveals the significant negative impact of Cr 2 (SO 4 ) 3 contamination on GDL and fuel cell performance, highlighting that changes in surface structure, reduced hydrophobicity, and increased mass transfer resistance are primary causes of performance degradation. The findings provide crucial insights for improving GDL materials, optimizing fuel cell manufacturing and operation processes, and addressing contamination issues in practical applications.

Carbon EnergyVol. 7(8)
Harbin Institute of Technology (CN), Southern University of Science and Technology (CN), Energy Research Institute (CN), Hydrogenics (Belgium) (BE)
Southern University of Science and Technology
Openalex Percentile: Top 12%
Fuel Cells and Related Materials
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.