Thermal performance of rectangular pyramid roughened solar air heater‐an experimental investigation

Abstract The present investigation is performed outdoors to explore the thermal performance (η th ) of a rectangular pyramid roughened solar air heater. The experiment was conducted on the roof of the Mechanical Department, MANIT Bhopal (latitude 23.25°, longitude 77.43°) during February–June 2023 between 10:00 AM and 3:00 PM at a test rig kept flat on the ground using six different mass flow rates (ṁ) while keeping one mass flow rate fixed for the entire day. The presence of rectangular pyramid roughness induces disturbances and enhances the mixing of primary and secondary flows. Consequently, this leads to a greater improvement in η th . The roughness parameters varied and investigated are the relative roughness height (e/D h ) varied from 0.033 to 0.054, the relative roughness pitch (p/e) varied from 8 to 20, and two novel geometrical parameters, the relative base length to width ratio (b L /b W ) and the roughness height to base length ratio (e/b L ) are introduced and varied as 1.25–2 and 0.35–0.63, respectively. The Reynolds number (Re) is varied in the range of 3350–13,350. η th is evaluated in terms of the collector heat removal factor (f hrf ) and the collector efficiency factor (f cef ). A maximum η th of 79.8% has been reported at e/D h = 0.047, p/e = 16, e/b L = 0.58, b L /b W = 1.5, and at ṁ = 0.0476 kg/s. F hrf and F cef are maximum at p/e = 16, e/D h = 0.047, b L /b W = 2, and e/b L = 0.63. Maximum and minimum F hrf were found to be 0.79 and 0.65, respectively Maximum and minimum F cef were found to be 0.87 and 0.68, respectively as 0.87 and 0.68 corresponding to the optimum parameters.

Authors

Institutions

Publication Details

Journal
Environmental Progress & Sustainable Energy
Published
2025-06-24
DOI
https://doi.org/10.1002/ep.70016
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal performance of rectangular pyramid roughened solar air heater‐an experimental investigation

Vikash Kumar, Arun Shrivastava
4 links
Environmental Progress & Sustainable Energy
Heat Transfer Mechanisms
article

Thermal performance of rectangular pyramid roughened solar air heater‐an experimental investigation

Vikash Kumar, Arun Shrivastava
article en

Abstract

Abstract The present investigation is performed outdoors to explore the thermal performance (η th ) of a rectangular pyramid roughened solar air heater. The experiment was conducted on the roof of the Mechanical Department, MANIT Bhopal (latitude 23.25°, longitude 77.43°) during February–June 2023 between 10:00 AM and 3:00 PM at a test rig kept flat on the ground using six different mass flow rates (ṁ) while keeping one mass flow rate fixed for the entire day. The presence of rectangular pyramid roughness induces disturbances and enhances the mixing of primary and secondary flows. Consequently, this leads to a greater improvement in η th . The roughness parameters varied and investigated are the relative roughness height (e/D h ) varied from 0.033 to 0.054, the relative roughness pitch (p/e) varied from 8 to 20, and two novel geometrical parameters, the relative base length to width ratio (b L /b W ) and the roughness height to base length ratio (e/b L ) are introduced and varied as 1.25–2 and 0.35–0.63, respectively. The Reynolds number (Re) is varied in the range of 3350–13,350. η th is evaluated in terms of the collector heat removal factor (f hrf ) and the collector efficiency factor (f cef ). A maximum η th of 79.8% has been reported at e/D h = 0.047, p/e = 16, e/b L = 0.58, b L /b W = 1.5, and at ṁ = 0.0476 kg/s. F hrf and F cef are maximum at p/e = 16, e/D h = 0.047, b L /b W = 2, and e/b L = 0.63. Maximum and minimum F hrf were found to be 0.79 and 0.65, respectively Maximum and minimum F cef were found to be 0.87 and 0.68, respectively as 0.87 and 0.68 corresponding to the optimum parameters.

Environmental Progress & Sustainable EnergyVol. 44(5)
Maulana Azad National Institute of Technology (IN)
Openalex Percentile: Top 86%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thermal performance of rectangular pyramid roughened solar air heater‐an experimental investigation — Vikash Kumar, Arun Shrivastava · Environmental Progress & Sustainable Energy (2025) | TGRS Research Map | TGRS