Axicons for improved resolution and depth of focus in adaptive optics scanning light ophthalmoscopy

Adaptive optics scanning light ophthalmoscopes are instrumental for studying the eye, yet they use truncated Gaussian illumination and are limited by diffraction, restricting resolution and depth of focus (DOF). Non-diffractive Bessel beams have emerged as an alternative. Here, we use two axicons configured as: (1) an extended DOF beam for resolving multiple retinal layers; and (2) an annular beam for increasing lateral resolution. We compare both approaches to truncated Gaussian illumination using a variety of metrics. Using Configuration 1, we successfully observed multiple retinal layers simultaneously. Using Configuration 2, we observed enhanced lateral resolution but decreased signal-to-noise ratio.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-06-24
DOI
https://doi.org/10.1364/boe.564398
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axicons for improved resolution and depth of focus in adaptive optics scanning light ophthalmoscopy

Ruth E. Woehlke, Robert F. Cooper
Biomedical Optics Express
Optical Coherence Tomography Applications
article

Axicons for improved resolution and depth of focus in adaptive optics scanning light ophthalmoscopy

Ruth E. Woehlke, Robert F. Cooper
article en

Abstract

Adaptive optics scanning light ophthalmoscopes are instrumental for studying the eye, yet they use truncated Gaussian illumination and are limited by diffraction, restricting resolution and depth of focus (DOF). Non-diffractive Bessel beams have emerged as an alternative. Here, we use two axicons configured as: (1) an extended DOF beam for resolving multiple retinal layers; and (2) an annular beam for increasing lateral resolution. We compare both approaches to truncated Gaussian illumination using a variety of metrics. Using Configuration 1, we successfully observed multiple retinal layers simultaneously. Using Configuration 2, we observed enhanced lateral resolution but decreased signal-to-noise ratio.

Biomedical Optics ExpressVol. 16(8)
Marquette University (US), Medical College of Wisconsin (US)
National Institutes of Health, National Center for Advancing Translational Sciences
Affordable and clean energy
Openalex Percentile: Top 86%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Axicons for improved resolution and depth of focus in adaptive optics scanning light ophthalmoscopy — Ruth E. Woehlke, Robert F. Cooper · Biomedical Optics Express (2025) | TGRS Research Map | TGRS