Agreement and comparative performance of the MobiLab rapid oncoprotein E6/E7 antigen test and Cobas 4800 high-risk human papillomavirus deoxyribonucleic acid test for cervical cancer screening in a low-resource setting: a cross-sectional study

Abstract Background: Persistent high-risk human papillomavirus is responsible for 95% of all cases of cervical cancer worldwide. Screening for high-risk genotypes has been acknowledged as the gold standard for the elimination of cervical cancer. However, most low- and middle-income countries have limited access to this screening method because ofa lack of adequate sustainable resources. Objective: This study aimed to compare the diagnostic accuracy of the rapid high-risk human papillomavirus 16/18 oncoprotein E6/E7 antigen test to that of the polymerase chain reaction (PCR) deoxyribonucleic acid test among women who presented to family planning and dysplasia clinics at Moi Teaching and Referral Hospital. Methods: This was a cross-sectional study performed between February and July 2024 to compare the diagnostic accuracy of the rapid high-risk human papillomavirus 16/18 oncoprotein E6/E7 antigen test to that of the polymerase chain reaction deoxyribonucleic acid test among women who underwent cervical cancer screening at Moi Teaching and Referral Hospital. Two hundred and fifty-seven (257) women aged 30 years and older were randomly selected for this study. A cervical swab was obtained from all participants for human papillomavirus polymerase chain reaction deoxyribonucleic acid testing, followed by cervical sample collection using the Delphi vaginal self-sampler for the rapid human papillomavirus oncoprotein E6/E7 antigen test. To achieve the objective of the study, sensitivity, specificity, positive predictive value, and negative predictive value were measured. Data on sociodemographicand clinical characteristics were collected and analysed. The significance of the data was set at a two-tailed p<0.05. The chi-squaretest was used to compare categorical variables. Fisher’s exact test or the Monte Carlo correction was used for the chi-square analysis when more than 20% of the cells had an expected count <5. Results: The sensitivity of the rapid oncoprotein E6 and E7 test was 99.33%, and the specificity was 99.07%. In addition, the positive predictive value and negative predictive value were 99.33% and 99.07%, respectively. Furthermore, the accuracy of the rapid oncoprotein E6/E7 test was 99.22%. These findings were statistically significant (p <0.001, 95% CI=0.98–1.00), and the AUC for the rapid oncoprotein E6/E7 test was 0.992. Conclusion: The accuracy of the rapid high-risk human papillomavirus mRNA oncoprotein E6/E7 antigen test is as good as that of the polymerase chain reaction deoxyribonucleic acid test for cervical cancer screening in low-resource settings.

Authors

Institutions

Publication Details

Journal
BMC Infectious Diseases
Published
2026-11-11
DOI
https://doi.org/10.1186/s12879-026-14538-2
Primary Topic
Cervical Cancer and HPV Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Agreement and comparative performance of the MobiLab rapid oncoprotein E6/E7 antigen test and Cobas 4800 high-risk human papillomavirus deoxyribonucleic acid test for cervical cancer screening in a low-resource setting: a cross-sectional study

Richard Mogeni, Paul Nyongesa, Benson Macharia, Benjamin Elly Odongo et al.
2 links
BMC Infectious Diseases
Cervical Cancer and HPV Research
article

Agreement and comparative performance of the MobiLab rapid oncoprotein E6/E7 antigen test and Cobas 4800 high-risk human papillomavirus deoxyribonucleic acid test for cervical cancer screening in a low-resource setting: a cross-sectional study

Richard Mogeni, Paul Nyongesa, Benson Macharia, Benjamin Elly Odongo, Kapten Muthoka, Peter Muhandale Itsura, M. W., Philip K. Tonui, Kibor Keitany, Talai KC, Njiru JN, Kosgei Wycliffe K, Mercy Kosgei, Philippe Amubuomombe Poli, Orango Omenge, Aruasa Wilson K, Banchiri Ruth Okero, Cheruiyot Edymond Kiplangat
article en

Abstract

Abstract Background: Persistent high-risk human papillomavirus is responsible for 95% of all cases of cervical cancer worldwide. Screening for high-risk genotypes has been acknowledged as the gold standard for the elimination of cervical cancer. However, most low- and middle-income countries have limited access to this screening method because ofa lack of adequate sustainable resources. Objective: This study aimed to compare the diagnostic accuracy of the rapid high-risk human papillomavirus 16/18 oncoprotein E6/E7 antigen test to that of the polymerase chain reaction (PCR) deoxyribonucleic acid test among women who presented to family planning and dysplasia clinics at Moi Teaching and Referral Hospital. Methods: This was a cross-sectional study performed between February and July 2024 to compare the diagnostic accuracy of the rapid high-risk human papillomavirus 16/18 oncoprotein E6/E7 antigen test to that of the polymerase chain reaction deoxyribonucleic acid test among women who underwent cervical cancer screening at Moi Teaching and Referral Hospital. Two hundred and fifty-seven (257) women aged 30 years and older were randomly selected for this study. A cervical swab was obtained from all participants for human papillomavirus polymerase chain reaction deoxyribonucleic acid testing, followed by cervical sample collection using the Delphi vaginal self-sampler for the rapid human papillomavirus oncoprotein E6/E7 antigen test. To achieve the objective of the study, sensitivity, specificity, positive predictive value, and negative predictive value were measured. Data on sociodemographicand clinical characteristics were collected and analysed. The significance of the data was set at a two-tailed p<0.05. The chi-squaretest was used to compare categorical variables. Fisher’s exact test or the Monte Carlo correction was used for the chi-square analysis when more than 20% of the cells had an expected count <5. Results: The sensitivity of the rapid oncoprotein E6 and E7 test was 99.33%, and the specificity was 99.07%. In addition, the positive predictive value and negative predictive value were 99.33% and 99.07%, respectively. Furthermore, the accuracy of the rapid oncoprotein E6/E7 test was 99.22%. These findings were statistically significant (p <0.001, 95% CI=0.98–1.00), and the AUC for the rapid oncoprotein E6/E7 test was 0.992. Conclusion: The accuracy of the rapid high-risk human papillomavirus mRNA oncoprotein E6/E7 antigen test is as good as that of the polymerase chain reaction deoxyribonucleic acid test for cervical cancer screening in low-resource settings.

BMC Infectious Diseases
Moi University (KE), Aga Khan University Hospital (PK), AMPATH (KE)
Good health and well-being
Cervical Cancer and HPV Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon