A Comparative Study of ViT-B16, DeiT, and ResNet50 for Peripheral Blood Cell Image Classification

This paper presents a comparative analysis of three advanced models, Vision Transformer (ViT-B16), Data-efficient Image Transformer (DeiT), and ResNet50, for the classification of peripheral blood cell (PBC) images. This study is focused on comparing the performance of these models, rather than introducing a novel approach. The study evaluates the models based on their accuracy, precision, recall, and F1-score on the PBC dataset. ViTB16 achieves an accuracy of 98.77%, significantly outperforming DeiT, which achieves an accuracy of 93.25%, and ResNet50, which achieves an accuracy of 73.01%. The results highlight the superior performance of ViT-B16 in terms of classification metrics, although DeiT demonstrates efficiency in data utilization and model complexity. ResNet50, while a robust convolutional neural network, shows lower accuracy in this specific task. This research provides valuable insights into the application of transformer-based models in medical image classification.

Authors

Institutions

Publication Details

Published
2024-11-03
DOI
https://doi.org/10.1109/afros62115.2024.11036935
Citations
1
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Study of ViT-B16, DeiT, and ResNet50 for Peripheral Blood Cell Image Classification

Mourtada Benazzouz, Mohammed Lamine Benomar, Younes Bekkal Brikci
1 citations
AI in cancer detection
0.35
article

A Comparative Study of ViT-B16, DeiT, and ResNet50 for Peripheral Blood Cell Image Classification

Mourtada Benazzouz, Mohammed Lamine Benomar, Younes Bekkal Brikci
article en
1 citations

Abstract

This paper presents a comparative analysis of three advanced models, Vision Transformer (ViT-B16), Data-efficient Image Transformer (DeiT), and ResNet50, for the classification of peripheral blood cell (PBC) images. This study is focused on comparing the performance of these models, rather than introducing a novel approach. The study evaluates the models based on their accuracy, precision, recall, and F1-score on the PBC dataset. ViTB16 achieves an accuracy of 98.77%, significantly outperforming DeiT, which achieves an accuracy of 93.25%, and ResNet50, which achieves an accuracy of 73.01%. The results highlight the superior performance of ViT-B16 in terms of classification metrics, although DeiT demonstrates efficiency in data utilization and model complexity. ResNet50, while a robust convolutional neural network, shows lower accuracy in this specific task. This research provides valuable insights into the application of transformer-based models in medical image classification.

University of Abou Bekr Belkaïd (DZ)
Openalex Percentile: Top 29%
AI in cancer detection
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.