A High-Sensitivity Microwave Resonator for Triclosan and Glyphosate Detection in Water

This work presents the design, fabrication, and testing of a circular split ring resonator (Cir-SRR) with an embedded interdigital capacitor (IDC) for emerging contaminant detection. The IDC attached to the outer ring gap of the Cir-SRR concentrates the electric field and improves the sensitivity of the resonator. According to measurements, the IDC/Cir-SRR resonates at 1.77 GHz and achieves a quality factor <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Q</i> of 295. The simulation reported a hot spot of 115.9204 dBV/m in the IDC detection zone. The resonant frequency shifts approximately 400 MHz when the liquid sample changes from water to ethanol. The sensitivity was studied using ethanol in deionized water. An average sensitivity of 1.53% was achieved in the relative permittivity range of 18–79. Triclosan and glyphosate were selected as emerging contaminants and were tested by dissolving them in a 50% ethanol-water mixture and water, respectively. Linear relationships between the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">S</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">21</sub> transmission parameter and concentration were found in the selected ranges of 0–50 μg/mL and 0–35 μg/mL for triclosan and glyphosate, respectively. A sensitivity of 6.87×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-2</sup> dB/(μg/mL) and a limit of detection (LOD) of 1.83 μg/mL were obtained with glyphosate solutions. In contrast, the values of 1.47×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-2</sup> dB/(μg/mL) and 1.18 μg/mL were obtained with triclosan solutions. The results suggest that this technology offers a viable approach for the rapid detection of emerging water contaminants.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3581626
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Sensitivity Microwave Resonator for Triclosan and Glyphosate Detection in Water

A.U. Chávez-Ramírez, Arcesio Arbelaez, José Herrera-Celis, José‐Luis Olvera‐Cervantes et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Advanced Chemical Sensor Technologies
0.67
article

A High-Sensitivity Microwave Resonator for Triclosan and Glyphosate Detection in Water

A.U. Chávez-Ramírez, Arcesio Arbelaez, José Herrera-Celis, José‐Luis Olvera‐Cervantes, Abigail González Zea
article en
1 citations

Abstract

This work presents the design, fabrication, and testing of a circular split ring resonator (Cir-SRR) with an embedded interdigital capacitor (IDC) for emerging contaminant detection. The IDC attached to the outer ring gap of the Cir-SRR concentrates the electric field and improves the sensitivity of the resonator. According to measurements, the IDC/Cir-SRR resonates at 1.77 GHz and achieves a quality factor <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Q</i> of 295. The simulation reported a hot spot of 115.9204 dBV/m in the IDC detection zone. The resonant frequency shifts approximately 400 MHz when the liquid sample changes from water to ethanol. The sensitivity was studied using ethanol in deionized water. An average sensitivity of 1.53% was achieved in the relative permittivity range of 18–79. Triclosan and glyphosate were selected as emerging contaminants and were tested by dissolving them in a 50% ethanol-water mixture and water, respectively. Linear relationships between the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">S</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">21</sub> transmission parameter and concentration were found in the selected ranges of 0–50 μg/mL and 0–35 μg/mL for triclosan and glyphosate, respectively. A sensitivity of 6.87×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-2</sup> dB/(μg/mL) and a limit of detection (LOD) of 1.83 μg/mL were obtained with glyphosate solutions. In contrast, the values of 1.47×10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-2</sup> dB/(μg/mL) and 1.18 μg/mL were obtained with triclosan solutions. The results suggest that this technology offers a viable approach for the rapid detection of emerging water contaminants.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Universidad Industrial de Santander (CO), National Institute of Astrophysics, Optics and Electronics (MX), Centro de Investigación y Desarrollo (ES), Universidad del Valle (NI), Center of Research and Technologic Development in Electrochemistry (MX)
Clean water and sanitation
Openalex Percentile: Top 30%
Advanced Chemical Sensor Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.