Suppressing the Static Magnetic Field Error Based on the Rb–Xe Coupling Effect in NMR Angular Velocity Sensor
The nuclear magnetic resonance (NMR) angular velocity sensor exhibits compactness and high precision, leveraging an in-situ rubidium (Rb) magnetometer to determine the precession frequencies of double-isotope Xe (<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">129</sup>Xe and <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">131</sup>Xe), which are critical for angular velocity determination. However, its performance is substantially affected by static magnetic field variations, which not only alter the precession frequencies of <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">129</sup>Xe and <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">131</sup>Xe but also induce shifts in Rb precession frequency, thereby introducing measurement errors in angular velocity. To mitigate this challenge, this study investigates the impact of static magnetic field shifts on the precession frequency measurement error and presents a suppression method based on the Rb-Xe coupling effect. This method comprehensively evaluates the influence of static magnetic field shifts on the Rb, <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">129</sup>Xe, and <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">131</sup>Xe magnetic moment signals, ultimately proposing a static magnetic field error suppression method. Notably, this approach effectively suppresses the static magnetic field error without influencing the measurement sensitivity. Experimental validation reveals a significant 48.8 % reduction in static magnetic field error. Long-term stability of precession frequency measurement error between <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">129</sup>Xe and <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">131</sup>Xe shows a 24.9 % reduction in the maximum variation and a 25.1% decrease in bias instability during 2-hour continuous monitoring. This innovative approach offers substantial benefits for advancing the performance and reliability of angular velocity sensor.
Authors
- Yibo Shao (ORCID: https://orcid.org/0009-0003-3634-9757)
- Jianli Li (ORCID: https://orcid.org/0000-0001-8195-3820)
- Zhanchao Liu (ORCID: https://orcid.org/0000-0003-0162-9217)
- Lan Xiao (ORCID: https://orcid.org/0000-0002-6379-9521)
- Hao Tian (ORCID: https://orcid.org/0000-0002-6186-5855)
- Xuelei Wang (ORCID: https://orcid.org/0000-0001-7807-0859)
Institutions
- Beihang University (CN)
Publication Details
- Journal
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/tim.2025.3579849
- Citations
- 1
- Primary Topic
- Atomic and Subatomic Physics Research
- Type
- article
- Field-Weighted Citation Impact
- 1.25
Funders
- National Science Fund for Distinguished Young Scholars